检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]天津城建大学环境与市政工程学院,天津300384 [2]天津市水质科学与技术重点实验室,天津300384
出 处:《工业水处理》2017年第12期43-47,共5页Industrial Water Treatment
基 金:国家科技支撑计划项目(2012BAB17B02)
摘 要:采用活性炭纤维作为电极材料,动态电吸附去除水中的2,4,6-三氯酚。考察了电压、极板间距、进水流量和沿程长度对三氯酚去除效果的影响,得出工艺最佳条件:电压1.0 V,极板间距4 mm,进水流量112.5 mL/min,沿程长度320 mm,三氯酚去除率达到98.31%。准一级动力学模型和Langmuir吸附等温线模型可较好地描述活性炭纤维对三氯酚的吸附行为。Activated carbon fiber as the electrode material has been used for removing 2,4,6-trichlorophenol(TCP)from water by dynamic electrosorption method,and the influences of voltage,plate spacing,influent flow rate and path length on TCP removing effect have been investigated.It is known that the optimum conditions are as follows:the voltage is 1.0 V,plate spacing 4 mm,influent flow rate 112.5 mL/min,and path length 320 mm.Under these conditions,the removing rate of TCP is 98.31%.The pseudo-first order kinetic model and the Langmuir adsorption isotherm model can be used for describing the adsorption behavior of ACF for TCP.
分 类 号:X703[环境科学与工程—环境工程]