酸化返排液电脱水效果影响因素分析  被引量:3

Analysis of Influence Factors for Electric Dehydration of Returned Acidizing Fluids

在线阅读下载全文

作  者:曹广胜[1] 李世宁[1] 马骁 李泽 杨晓雨[1] 何奇[1] 

机构地区:[1]东北石油大学石油工程学院,黑龙江大庆163318 [2]冀北油田分公司工程监督中心,河北唐山063299

出  处:《石油化工高等学校学报》2018年第1期57-60,共4页Journal of Petrochemical Universities

基  金:国家自然科学基金项目(51574089)

摘  要:针对油井酸化后返排液乳化现象严重,无法进入电脱流程的问题,通过室内模拟实验从温度、pH、含水率、返排液油相、返排液水相、油中泥质、含铁化合物等方面进行了探究,发现当乳化不严重时返排液水相和含水率对电脱影响不大,温度升高有利于返排液破乳,pH处于中性时最适合返排液破乳,而氢氧化铁胶体包裹着原油、油中污泥和游离水,形成了处于油水两相之间的电导率极高的中间层,是导致返排液过流的主要原因。The acidizing cleanup emulsion phenomenon is serious, and it can not enter the power off process. In view of the above problems, indoor simulation experiments were carried out to explore the influence of temperature, pH value, moisture content, the oil phase of the returned liquid, the water phase of the returned liquid, the iron-containing compound and the mud content on electric dehydration of returned acidizing fluids. It was found that when the impurities in the oil were less, the water phase and water content of the returned aeidizing fluids had little effect on the electric dehydration, the increasing of the temperature was beneficial to the effluent demulsification, and neutral pH value was the most suitable condition for the demulsification of the returned fluids. The ferric hydroxide colloid which was wrapped with crude oil, sludge and free water in oil, forming a very high conductivity intermediate layer between the oil phase and the water phase, was the main cause of electric dehydrator trip.

关 键 词:酸化 返排液 电脱水 氢氧化铁 

分 类 号:TE832[石油与天然气工程—油气储运工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象