检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陶秋根[1] 刘鹤忠[1] 邓文祥[1] 戴建忠 TAO Qiu-gen;LIU He-zhong;DENG Wen-xiang;DAI Jian-zhong(Eest China Electric Power Design Institute Co.Ltd., Shanghai 200063, Chin)
出 处:《电力勘测设计》2018年第1期26-30,共5页Electric Power Survey & Design
摘 要:随着新的国家环保政策实施,对现役燃煤机组在原设计时执行的烟气污染物控制排放标准不能满足现有国家环保要求的均需要技术改造。针对徐州电厂改造后的烟气污染物排放指标除了满足国家的环保要求外,同时满足神华集团、国华电力公司要求,做到高品质绿色发电的要求。其中除尘改造后烟尘的排放浓度≤3 mg/Nm3。With the implementation of the new national environmental protection policy, it is necessary for the active coal-fired units to control the emission standards of flue gas pollutants which can not meet the requirements of environmental protection. In accordance with the requirements of the national environmental protection requirements, the flue gas pollutant emissions after the transformation of Xuzhou power plant can meet the requirements of Shenhua Group and Guohua Electric Power company. The flue gas dust emission concentration less than 3mg/Nm3 after the Dust removal equipment modification.
分 类 号:TM621[电气工程—电力系统及自动化]