徐州电厂静电除尘器改造及高频电源的技术应用  被引量:5

Retrofit of Electrostatic Precipit and Technical Application of High Frequency Power Suply in Xuzhou Power Plant

在线阅读下载全文

作  者:陶秋根[1] 刘鹤忠[1] 邓文祥[1] 戴建忠 TAO Qiu-gen;LIU He-zhong;DENG Wen-xiang;DAI Jian-zhong(Eest China Electric Power Design Institute Co.Ltd., Shanghai 200063, Chin)

机构地区:[1]华东电力设计院有限公司,上海200063

出  处:《电力勘测设计》2018年第1期26-30,共5页Electric Power Survey & Design

摘  要:随着新的国家环保政策实施,对现役燃煤机组在原设计时执行的烟气污染物控制排放标准不能满足现有国家环保要求的均需要技术改造。针对徐州电厂改造后的烟气污染物排放指标除了满足国家的环保要求外,同时满足神华集团、国华电力公司要求,做到高品质绿色发电的要求。其中除尘改造后烟尘的排放浓度≤3 mg/Nm3。With the implementation of the new national environmental protection policy, it is necessary for the active coal-fired units to control the emission standards of flue gas pollutants which can not meet the requirements of environmental protection. In accordance with the requirements of the national environmental protection requirements, the flue gas pollutant emissions after the transformation of Xuzhou power plant can meet the requirements of Shenhua Group and Guohua Electric Power company. The flue gas dust emission concentration less than 3mg/Nm3 after the Dust removal equipment modification.

关 键 词:高品质绿色发电 高频电源技术 烟尘排放浓度 

分 类 号:TM621[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象