微波铁氧体介电常数测量值的尺寸因素修正  被引量:2

Correction of specimen's dimension to the measured value of dielectric constant for microwave ferrites

在线阅读下载全文

作  者:韩志全[1] 张方远 

机构地区:[1]西南应用磁学研究所,四川绵阳621000 [2]东阳富仕特磁业有限公司,浙江东阳322105

出  处:《磁性材料及器件》2018年第1期23-26,30,共5页Journal of Magnetic Materials and Devices

摘  要:用普通陶瓷工艺制备了饱和磁化强度M_s为96 kA/m的钇钙钒石榴石铁氧体材料,在10.7 GHz下按照GB9633(等同IEC60556标准)测量了石榴石铁氧体的介电常数ε'及介电损耗tanδ_ε。实验表明测得的ε'值随试样直径的减小而降低。由计算公式分析了ε'随试样直径减小而降低的原因。给出了ε'测量值与试样直径关系的经验公式及ε'的尺寸修正系数,修正以后可以基本上消除ε'测量值中由试样尺寸引起的误差。最后讨论了介电常数和介电损耗的精准测量问题。Polycrystalline YCaVIGs garnet materials with saturation magnetization of 96kA/m were prepared by conventional ceramic process. According to the National Standard GB9633( equal to IEC 60556 standard ) for gyro-magnetic materials, the dielectric constant ?? and the dielectric loss angle tangent tan?? were measured at 10.7 GHz for garnet specimens with different diameters. The results show that with decreasing samples’ diameter the ?? value decreases. This result is discussed with the ?? calculating equation. To correct the calculation deviation of the measured dielectric constant ?? value, a dimension correction-coefficient and an experimental equation about the dimension dependence of the ?? value were proposed. Using the dimension correction equation, the error of the measured ?? value can be corrected basically. The problem of the measurement of dielectric constant and dielectric loss with more accurate was discussed.

关 键 词:微波铁氧体 介电常数 尺寸修正 旋磁参数测量 石榴石 

分 类 号:TM277.3[一般工业技术—材料科学与工程] TM934.33[电气工程—电工理论与新技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象