检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:林子良[1] 鲍洋洋[1] 李金荣[1] 林泽安[1]
机构地区:[1]合肥通用机械研究院
出 处:《制冷与空调》2018年第1期46-51,45,共7页Refrigeration and Air-Conditioning
摘 要:制冷空调产品的能效测量系统测量数据质量的高低,决定了产品能效标识工作质量的高低。对于测量系统的分析及其测量结果的不确定度评价,已有的相关标准只是孤立地对单一概念进行论述,无具体的应用示例。本文通过系统论述说明和应用示例,以期达到对能效测量系统能力评价的充分理解,并对能效测量系统的管理提供帮助。The quality of measured data obtained by the energy efficiency measurement system for the refrigeration and air-conditioning product, determines the work quality of product energy efficiency label. For measurement system analysis and uncertainty evalua-tion of measurement results? the related standards only discuss some conceptions in isola-tion, without applied example. Through expounding systematically and applied example, it is in the hope of understanding the capability evaluation of energy efficiency measure-ment system, and offering help for the management of energy efficiency measurement sys-tem.
关 键 词:测量系统分析 能力评价 测量不确定度 制冷 空调
分 类 号:TB657.2[一般工业技术—制冷工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28