检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王琪 梁静秋[1] 梁中翥[1] 吕金光[1] 王维彪[1] 秦余欣[1] 王洪亮
机构地区:[1]中国科学院长春光学精密机械与物理研究所应用光学国家重点实验室,吉林长春130033 [2]中国科学院大学,北京100049
出 处:《中国光学》2018年第1期92-99,共8页Chinese Optics
基 金:国家自然科学基金资助项目(No.61575193;No.61376122;No.61027010;No.61627819);吉林省科技发展计划资助项目(No.20150520101JH;No.20150101049JC;No.20150204072GX;No.20130206010GX);长春市科技计划资助项目(No.2013261);应用光学国家重点实验室开放基金资助项目~~
摘 要:为了在复杂及伪装的红外背景中识别出小温差目标,本文提出了一种基于分孔径的偏振成像系统结构,并对分孔径偏振成像系统所采用的分孔径成像系统及中继成像系统进行了设计研究。首先,根据Stokes矢量介绍了系统的工作理论和光学结构;其次,在现有探测器的结构参数要求下,计算出了光学系统的偏心量等参数,选择硅、锗作为透镜材料。在此基础上,确定了分孔径成像系统结构和中继成像系统结构。接着使用离轴偏心多重结构设计方法对初始结构进行了优化,研究了将普通红外物镜转变为具有实入瞳的像方远心结构的方法;最后,完成了分孔径成像系统和中继成像系统的整体系统匹配。设计结果表明,整体系统的调制传递函数在探测器奈奎斯特频率为17 lp/mm处大于0.6,能够满足系统的设计要求。本文设计的结构可以对探测目标实现实时偏振成像,且具有结构紧凑的优点。In order to identify the target with little temperature difference in complicated and disguised infrared background,a decentered aperture-divided polarization imaging system is introduced in this paper. The design of decentered aperture-divided imaging system and relay imaging system adopted in decentered aperture-divided polarization imaging system are also studied. Firstly,the working theory and optical structure of the systemare introduced according to the Stokes vectors. Secondly,the parameters of the optical system such as the eccentricity are calculated under the requirements of the structural parameters of the existing detectors in the laboratory,and silicon and germanium are selected as the lens materials. According to these parameters,both the structure of aperture-divided imaging system and that of relay imaging system are determined on this basis.Then the off-axis eccentric multi-structure design method is used to optimize the initial structure. The transformation method from ordinary infrared objective to image-side telecentric structure with real entrance pupil is studied. Finally,the overall system matching of aperture-divided imaging system and relay imaging system is completed. The results show that the overall system modulation transfer function( MTF) at Nyquist frequency of the detector of 17 lp/mm is greater than 0. 6,which can meet the system design requirements. The structure introduced in this paper can detect the real-time polarization of the target,and possesses the advantages of compact structure.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222