检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张彦辉[1] 张良圣[1] 常阳[1] 范增伟[1] 郭冬发[1]
出 处:《铀矿地质》2018年第2期105-111,共7页Uranium Geology
摘 要:研究建立了增压-微波消解电感耦合等离子体质谱法测定含难溶矿物(含铌钽铀矿物、锆石等)岩石样品中微量元素的测试方法。该技术有效地解决了传统湿法消解方法不能完全消解含难溶矿物(含铌钽铀矿物、锆石等)岩石样品的难题。根据超高压-微波消解原理,自行设计加工了电加热增压消解装置一台。该装置的技术创新在于对含难溶矿物岩石样品采用了在同一消解罐中先微波消解再增压消解的方式,解决了微波消解到增压消解的转换问题,实现了对含难溶矿物岩石样品的无交叉污染、低本底、快速地增压-微波消解。通过一系列研究获得了含难溶矿物(含铌钽铀矿物、锆石等)岩石样品的微波-增压消解条件参数,然后采用电感耦合等离子体质谱(ICP-MS)法测定含难溶矿物岩石样品中微量元素含量。经标准物质测试验证,分析方法的定量限为0.004~0.084μg/g,精密度小于5%,测量相对误差小于10%,该方法能满足行业分析测试质量的控制要求。A pressurize-microwave inductively coupled plasma mass spectrometry was established in this study with the purpose of determining trace elements in rock samples containing refractory minerals(niobium and tantalum bearing uranium minerals, zircon). The problem for traditional wet digestion method which cannot dissolve rock samples containing refractory minerals(niobium and tantalum bearing uranium minerals, zircon) completely was solved effectively by this technology. An electrical heating pressurized-microwave device was designed according to the principle of ultra-high pressure simulation-microwave digestion. The technical innovation of the device is that the rock samples containing refractory minerals were digested by microwave-digestion device and solved the problem of switching the sample from the microwave digestion device to pressurized digestion device by pressurized-digestion device in the same digestion jar, which achieve a rapid pressurized-microwave digestion method for rock samples containing refractory minerals without cross contamination and with low cost. The Pressurize-microwave digestion parameters for rock samples containing refractory minerals(niobium and tantalum bearing uranium minerals, zircon) were obtained by this paper and the inductively coupled plasma mass spectrometry(ICP-MS) was used to determine trace elements for rock samples containing refractory minerals, which satisfy the requirement of fast and accurate testing for uranium geological exploration. The method has been verified by certified reference materials analysis and the quantitative limits is of 0.004 — 0.084 μg/g, precision is of less than 5%, measuring relative error is less than 10%, which satisfy the requirement of quality control for analytical testing business.
关 键 词:增压-微波消解 电感耦合等离子体质谱法 含难溶矿物岩石样品
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3