摘 要:对全国五大气候区的16个主要城市办公建筑的白天及夜间空调冷负荷进行计算,得到夜间空调冷负荷占白天空调冷负荷比例随气候区的南移逐渐增大的变化规律。研究结果可为不同气候区太阳能空调系统中蓄能装置容量匹配提供设计依据,同时为制冷空调系统优化运行提供理论指导。The air-conditioning cooling loads of office building during the daytime and nighttime in sixteen major cities in five climate regions of China are calculated.It is found that the ratio of the air-conditioning load during the nighttime to the one during the daytime increases gradually from north to south.The research results can provide the design basis for the match of the capacity of energy storage device for solar air-conditioning system in different climate regions,as well as the theoretical guidance for the optimal operation of refrigeration and air-conditioning system.