林氏腰椎提拉旋转斜扳手法力学特点分析  被引量:8

Analysis on Mechanical Characteristics of Lin’s Lumbar Vertebral Manipulation by Lifting-Rotating and Oblique-Pulling

在线阅读下载全文

作  者:范志勇[1] 李黎 田强[1] 王金玲[3] 赖淑华[1] 郭汝松[1] 吴山[1] 

机构地区:[1]广东省中医院推拿科,广州510120 [2]安徽省第二人民医院中医科,合肥230000 [3]广州中医药大学第二临床医学院,广州510405

出  处:《医用生物力学》2018年第1期70-75,共6页Journal of Medical Biomechanics

基  金:广东省自然科学基金项目(2014A030313406);广东省科技厅科研项目(2014A020212275);广东省中医药局科研立项资助课题(20141089);广东省中医药科学院研究专项(YN2014PJR201)

摘  要:目的采用多点薄膜压力测试系统研究腰椎提拉旋转斜扳手法,以阐明手法的力学特点。方法 21名男性推拿操作者分专家组、熟练者组、初学者组,连续在压力测试系统上操作7次,每人均重复3次,将收集的图形及数据指标进行处理分析。结果专家组手法操作时间-力曲线的图形规律,平均预加载力为(147.25±26.04)N,持续时间为(0.98±0.20)s,谷值平均值(79.22±9.50)N,最大冲击力(706.26±56.21)N,扳动时间(0.44±0.09)s,扳动速度(1 666.33±411.91)N/s,冲量(310.95±56.67)N·s。熟练者手法与专家组手法图形基本相似,各组指标相差不大,但平均最大冲击力相对较小,为(464.51±53.49)N。初学者手法图形轨迹大致可分为3类,Ⅰ类杂乱无章型,无规律可循;Ⅱ类只有冲击相无预加载相,且最大冲击力大小不一;Ⅲ类既有冲击相又有预加载相,且力量较稳定,但两者力度均偏小。结论多点薄膜压力测试系统可很好地显示林氏腰椎提拉旋转斜扳手法力学特点,是林氏手法动力学参数量化研究较理想的测试工具。试验结果为手法的直观显示、量化、标准化提供了科学依据。Objective To study the mechanical characteristics of lumbar vertebral manipulation by lifting-rotating and oblique-pulling using multi-film pressure measurement system. Methods Twenty-one male operators were divided into groups of experts,skilled operators and beginners. Everyone completed 7 actions of Lin's lumbar manipulation continuously,and repeated 3 times. The graphs and data were collected and processed. Results The time-force curve by the experts had regularity. The average pre-load force was( 147. 25 ± 26. 04) N,duration was( 0. 98 ± 0. 20) s,the average minimum force was( 79. 22 ± 9. 50) N,the maximum impact force was( 706. 26 ±56. 21) N,the flip time was( 0. 44 ± 0. 09) s,and flip speed was( 1 666. 33 ± 411. 91) N/s,the impulse was( 310. 95 ± 56. 67) N·s. The curve graphs and the index by the skilled operators were similar to those by the experts,but the average maximum impact force was( 464. 51 ± 53. 49) N,which was relatively smaller. The curve graphs by the beginners could be broadly divided into three categories. Class Ⅰ was chaotic and unregulated; Class Ⅱ only had impact force and did not have pre-load force,and the maximum impact force varied in size; Class Ⅲ had both impact force and pre-load force,but the forces were relatively small and stable. Conclusions The multi-film pressure measurement system can preferably display the mechanical characteristics of manipulation by lifting-rotating and oblique-pulling,which is an ideal testing tool for quantitative research on mechanical parameters of Lin's lumbar vertebral manipulation. The experimental results provide a scientific basis for visualization,quantification and standardization of the manipulation.

关 键 词:腰椎提拉旋转斜扳法 手法 力学特点 

分 类 号:R318.01[医药卫生—生物医学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象