检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘巍[1,2] 齐雅晨 蒋吉春 李金旭 周丽娟[3] 花磊 侯可勇[1] 李海洋[1]
机构地区:[1]中国科学院大连化学物理研究所,中国科学院分离分析化学重点实验室,辽宁大连116023 [2]中国科学院大学,北京100039 [3]吉林大学仪器科学与电气工程学院,吉林长春130026
出 处:《质谱学报》2018年第2期141-148,共8页Journal of Chinese Mass Spectrometry Society
基 金:国家自然科学基金(21375129); 863专项(2014AA06A507)资助
摘 要:室内装修造成的苯系物污染严重影响居民的生命健康。本研究设计了一种新型螺旋管状膜固相萃取进样装置,并与便携式单光子电离-飞行时间质谱仪(SPI-TOF MS)联用,用于空气中痕量苯系物的现场快速检测。螺旋的结构设计可以有效地增加管状膜的长度,在14min内即可完成苯、甲苯和二甲苯的检测,灵敏度分别提高了32.1、71.8和129.9倍,线性相关系数(R^2)均大于0.990 0,定量限(LOQ)分别低于33.3、67.8和93.6μg/m^3,能够满足国家规定的室内空气苯、甲苯和二甲苯的排放限值。重复测试8次,三者的相对标准偏差(RSD)分别为3%、1.7%和2.4%。该便携式质谱仪体积仅为(29×40×31)cm^3,质量为27kg,有望用于室内空气低浓度苯系物的现场多点快速检测。Benzene series emitted from indoor decorating materials seriously affect people's health.In this study,an innovative helical membrane solid-phase extractioninlet was designed and coupled to a portable single photon ionization-time of flight mass spectrometry(SPI-TOF MS)for in situ and rapid detection of trace benzene series in air.A hollow fiber membrane(HFM)was applied to adsorb the benzene series,and the membrane material was polydimethylsiloxane(PDMS).In the membrane extraction device,the length of the HFM was prominently increased with the helical structural design of the HFM.The installation length of the HFM was as long as 150 cm,but the volume of the membrane extraction device was only(3.14×484×92)mm^3.The problem with traditional membrane inlet that had a small membrane area was solved.The operating parameters of the membrane extraction device were optimized,which mainly targeted for the sampling flow rate,desorption temperature and enrichment time.As a result,the optimal sampling flow rate was found to be 600 mL/min,the optimal desorption temperature was 180 ℃ and the enrichment time was selected as 5 min.Under the optimal conditions,compared with the direct capillary sampling,the detection sensitivity of the benzene,toluene and xylene were enhanced 32.1,71.8 and 129.9 folds within14 min analytical period,respectively.The concentration range of 69.6-3 482.1,82.1-4 107.1 and 94.6-4 732.1μg/m3 of the benzene,toluene and xylene standard gas were tested for quantitative analysis.As a result,the linear correlation coefficient(R^2)of the three target compounds were all greater than 0.990 0.Based on the standard curves and the signal-to-noise(S/N)ratios,the limits of quantitation(LOQs,S/N=10)of the benzene,toluene and xylene were calculated as 33.3,67.8 and 93.6μg/m^3,respectively,which were much lower than the legal limit of BTX in room air.In addition,3 482.1,4 107.1 and 4 732.1μg/m^3 standard samples for benzene,toluene and xylene were tested by this system for 8 cycles w
关 键 词:螺旋管状膜固相萃取进样 单光子电离 便携式飞行时间质谱仪 苯系物 现场检测
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222