检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]Shanghai Key Laboratory of All Solid-State Laser and Applied Techniques, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China [2]University of Chinese Academy of Sciences, Beijing 100049, China
出 处:《Chinese Physics B》2018年第2期380-384,共5页中国物理B(英文版)
基 金:Project supported by the National Natural Science Foundation of China(Grant Nos.61405212,61377062,61405218,and 61775225);Scientific Innovation Fund of Chinese Academy of Sciences(Grant No.CXJJ-17S010)
摘 要:A theoretical model of the fiber Bragg grating Fabry–Perot(FBG-FP) transmission spectrum considering loss of FBG and intra-cavity fiber is presented. Several types of FBG-FPs are inscribed experimentally, and their spectra are measured.The results confirm that weak intra-cavity loss is enhanced at the resonance transmission peak, that is, loss of transmission peaks is observably larger than other wavelengths. For FBG-FPs with multi resonance peaks, when the resonance peak wavelength is closer to the Bragg wavelength, the more significant loss effect of resonance transmission peak is exhibited.The measured spectra are fitted with the presented theoretical model. The fitted coefficient of determinations are near 1,which proves the validity of the theoretical model. This study can be applied to measure FBG loss more accurately, without a reference light. It can play an important role in FBG and FBG-FP writing process optimization and application parameter optimization.A theoretical model of the fiber Bragg grating Fabry–Perot(FBG-FP) transmission spectrum considering loss of FBG and intra-cavity fiber is presented. Several types of FBG-FPs are inscribed experimentally, and their spectra are measured.The results confirm that weak intra-cavity loss is enhanced at the resonance transmission peak, that is, loss of transmission peaks is observably larger than other wavelengths. For FBG-FPs with multi resonance peaks, when the resonance peak wavelength is closer to the Bragg wavelength, the more significant loss effect of resonance transmission peak is exhibited.The measured spectra are fitted with the presented theoretical model. The fitted coefficient of determinations are near 1,which proves the validity of the theoretical model. This study can be applied to measure FBG loss more accurately, without a reference light. It can play an important role in FBG and FBG-FP writing process optimization and application parameter optimization.
关 键 词:fiber Bragg grating Fabry–Perot cavity intra-cavity loss transmission characteristics
分 类 号:TN253[电子电信—物理电子学]