检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:曹碧辉 陈德基[1] 梁宝霞 练辉[1] 张振峰 杨彦鸿 冯云飞 CAO Bihui, CHEN Deji, LIANG Baoxia , LIAN Hui, ZHANG Zhenfeng, YANG Yanhong, FENG Yunfei(Department of Radiology, the Second Affiliated Hospital of Guangzhou Medical University, Guangzhou 510260, Chin)
机构地区:[1]广州医科大学附属第二医院放射科,广东广州510260
出 处:《中国介入影像与治疗学》2018年第4期213-216,共4页Chinese Journal of Interventional Imaging and Therapy
基 金:国家自然科学基金(81461168028);2016年广东省教育厅青年创新人才类项目(2016KQNCX137)
摘 要:目的探讨锥形束CT(CBCT)联合iGuide引导系统在经皮经胸肺穿刺活检术(PTNB)中的应用价值。方法纳入30例因肺部单发病灶接受PTNB的患者。CBCT扫描后,通过iGuide引导系统和三维类CT多平面重组图像规划穿刺路径。采用18G同轴切割针行穿刺活检。记录手术相关资料、穿刺并发症及辐射剂量。结果 30例患者中,穿刺活检病理结果显示恶性病变24例,良性病变6例;28例符合最终病理诊断,1例为取材不够,但重新取材后的病理结果符合最终病理诊断,1例为假阴性结果。PTNB诊断肺部病变的准确率、敏感度、特异度、阳性预测值及阴性预测值分别为96.67%(29/30)、96.00%(24/25)、100%(5/5)、100%(24/24)及83.33%(5/6)。平均手术时间为(13.03±3.61)min,平均有效辐射剂量为(7.95±4.57)mSv。活检术后CBCT复查发现气胸6例(6/30,20.00%),咯血3例(3/30,10.00%)。结论CBCT联合iGuide引导系统引导下PTNB具有较高诊断准确率和安全性以及合理的辐射暴露。Objective To observe the clinical value of cone-beam computed tomography (CBCT) combined with iGuide system in percutaneous transthoracic needle biopsy (PTNB) of pulmonary lesions. Methods A total of 30 patients with solitary lung lesion underwent PTNB procedures were enrolled. The needle path was planned with iGuide system and 3D CT-like MPR images after CBCT. A coaxial system with 18-gauge cutting needle was used for biopsy. Procedure related data, complications and radiation exposure of patients were recorded. Results Among 30 patients, malignant lesions were found in 24, and benign lesions were in 6 patients. On PTNB, 28 patients were correctly diagnosed, 1 case was with insufficient samples but obtained correct pathologic result with second biopsy, 1 case was false-negative finding. The diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value of PTNB in diagnosis of lung diseases was 96.67% (29/30), 96.00% (24/25), 100% (5/5), 100% (24/24) and 83.33% (5/6), respectively. The mean procedure time was (13.03±3.61)min, and exposure dose was (7.95±4.57)mSv. After PTNB procedures, pneumothorax and hemoptysis occurred in 6 (6/30, 20.00%) and 3 (3/30, 10.00%) patients, respectively. Conclusion CBCT combined with iGuide system for guiding PTNB is accurate and safe with reasonable radiation exposure.
关 键 词:肺疾病 活组织检查 锥形束计算机体层摄影术 辐射剂量
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.15.189.95