检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]北京航空航天大学,100191 [2]河北恒润集团有限公司,衡水053000
出 处:《混凝土与水泥制品》2018年第4期43-46,共4页China Concrete and Cement Products
基 金:河北省科技计划项目"PCCP智能监测;检测及缺陷定位技术研究"(162176224D)
摘 要:预应力钢筒混凝土管被广泛应用于水利工程,运行过程中的环境腐蚀或管压操作不当,会导致管内高强钢丝的腐蚀或断裂,进而导致泄漏等事故。目前,普遍采用正交电磁检测技术对PCCP的断丝状态进行评估,本文应用有限元数值计算方法建立了PCCP检测系统全尺寸仿真模型,给出了断丝发生后电磁检测信号的畸变特征,并分析了断丝数量、检测频率等因素对畸变特征的影响,验证了电磁检测法的有效性,以期对PCCP实际工程应用提供参考。Pre-stressed Concrete Cylinder Pipe has been widely used in water conservancy projects. During the operation of PCCP, environmental corrosion or improper operation will lead to corrosion or fracture of high strength steel wire in the pipe, resulting in leakage and other accidents. Currently, orthogonal electromagnetic detection method has been widely used to test the broken wire and assess the health PCCP. Full size simulation model of the PCCP detection system is built by finite element (FE) method. The distortion Characteristics of electromagnetic detection signal is given for occurrence of the broken wire. The influences of broken wire number and detection frequency are also analyzed. The simulation results verify the effectiveness of the electromagnetic testing method, and provide a reference for practical engineering application.
分 类 号:TU525[建筑科学—建筑技术科学]