一段转化炉下集气管局部超温原因分析、监控及预防措施  

Cause Analysis,Monitoring and Preventive Measures of Local Over-Temperature Problem in the Outlet Manifold of Primary Reformer

在线阅读下载全文

作  者:李敬珂 LI Jingke(Henan Energy Chemical Group Zhongyuan Dahua Co., Puyang 457004, Chin)

机构地区:[1]河南能源化工集团中原大化公司,河南濮阳457004

出  处:《化肥工业》2018年第2期53-54,76,共3页Chemical Fertilizer Industry

摘  要:由于一段转化炉的4根下集气管和集气总管均出现过局部不同程度的超温现象,故在年度大修时全部予以更换,但开车正常后不久再次出现局部不同程度的超温现象。分析了超温的原因,探讨其监控及预防措施,以保证一段转化炉安全稳定运行。As local over-temperature problem exists in four outlet manifolds and gas gathering manifold of primary reformer, all of them were replaced during annual overhaul. However, the problem happened again shortly alter normally driving. The reason of local over-temperature problem is analyzed, monitoring and preventive measures are provided to ensure the safe and stable operation of primary reformer.

关 键 词:集气管 超温 原因分析 

分 类 号:TQ113.25[化学工程—无机化工]

 