双源CT低管电压联合迭代重建在非心电门控大螺距扫描主动脉CTA中的应用  被引量:2

Application of Non-ECG Gated High-pitch Spiral Mode Dual-source CT Low Tube Voltage Combined with Iterative Reconstruction in Aorta CTA

在线阅读下载全文

作  者:孟欣怡 王照谦[1] 杨志强[1] 贾崇富[1] 王浩[1] 孙喜霞[1] MENG Xin-yi;WANG Zhao-qian;YANG Zhi-qiang(Department of Cardiac CT,the First Affiliated Hospital of Dalian Medical University,Dalian 116011, China)

机构地区:[1]大连医科大学附属第一医院心脏CT检查科,辽宁大连116011

出  处:《医学与哲学(B)》2018年第4期41-44,48,共5页Medicine & Philosophy(B)

摘  要:探讨双源CT低管电压联合迭代重建在非心电门控大螺距(Flash)扫描主动脉CTA的图像质量及可行性。将60例行主动脉CTA检查的患者随机分成A、B两组,A组采用100k V Flash扫描,B组采用80k V Flash扫描,分别进行FBP重建(A_1、B_1组)和迭代重建(A_2、B_2组);对4组主动脉图像质量进行主观及客观评价。分析A、B组的有效辐射剂量,A_1、A_2组,B_1、B_2组及A_1、B_2组的图像质量是否有统计学差异。A_1、A_2和B_1、B_2组不同测量层面的CT值均无统计学差异,噪声、SNR及CNR均有显著统计学差异(P<0.01);A_1、B_2组不同测量层面的CT值和噪声均有显著统计学差异(P<0.01),SNR和CNR均无统计学差异(P>0.05);A_1、A_2组及A_1、B_2组图像质量评分无统计学差异(P=0.557/P=0.643),B_1、B_2组图像质量评分有统计学差异(P=0.030)。双源CT Flash扫描低管电压联合迭代重建主动脉CTA成像,能在获得满足诊断要求图像质量的同时显著降低辐射剂量。To investigate the image quality and feasibility of dual-source CT low tube voltage combined with iterative reconstruction of non-ECG-gated high-pitch spiral mode( Flash) in aorta CTA. 60 patients who underwent aorta CTA were randomly divided into2 groups: patients in group A were scanned with 100 k V Flash,patients in group B were scanned with 80 k V Flash,reconstructed with FBP( group A1 and B1) and iterative( group A1 and B2) respectively. Subjective and objective evaluation of the image quality was done in four groups. The CT value between group A1 and group A2,group B1 and group B2 had no significant difference( P〉0. 05). The noise,SNR and CNR of group A1,A2 had significant difference with that of group B1,B2 respectively( P〈0. 05).The CT value and noise between group A1 and group B2 had significant difference( P〈0. 05),but SNR and CNR between group A1 and group B2 had no significant difference( P〉0. 05). The image quality scores between group A1 and group A2,group A1 and group B2 had no significant difference( P = 0. 557/P = 0. 643),the image quality scores between group B1 and group B2 had significant difference( P = 0. 030). Dual-source CT Flash low tube voltage combined with iterative reconstruction of aortic CTA imaging can acquire high quality image for diagnosis while significantly reducing the radiation dose that can be used for clinical aortic CTA examination.

关 键 词:主动脉CTA 大螺距扫描 迭代重建 

分 类 号:R543.1[医药卫生—心血管疾病]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象