PV/T和GHP再生的转轮除湿空调系统仿真模型研究  

Simulation research of dessicant wheel air conditioning system regenerated by PV/T and GHP

在线阅读下载全文

作  者:郝红[1] 辛鹏 刘晓媛 于国鑫 HAO Hong;XIN Peng;LIU Xiao-yuan;et al

机构地区:[1]沈阳建筑大学,辽宁沈阳110168

出  处:《节能》2018年第4期25-30,共6页Energy Conservation

摘  要:首先利用MATLAB软件模拟出了除湿转轮子系统、GHP子系统和PV/T子系统的仿真模块,并根据子系统建立一整套系统的仿真模型;对于再生温度不同时除湿转轮出口空气的温度与湿度、冷凝器入口水温不同时系统的冷凝温度和冷凝压力以及不同时刻空气集热器出口的温度进行了仿真模拟,并将结果和实验数据进行对照,吻合较好。MATLAB software is used to simulate the modules of the dehumidifier wheel subsystem, GHP subsystem and PV/T subsystem, and complete system simulation model is set up according to the subsystem. The temperature and humid-ity of the outlet of dessicant wheel for different regeneration temperatures, the condensation temperature and the condensing pressure of different condenser inlet water temperature and the temperature of the outlet of the air collector at different time are simulated. The simulation results are in good agreement with the experimental data.

关 键 词:除湿转轮 燃气热泵 PV/T系统 仿真模拟 

分 类 号:TM9[电气工程—电力电子与电力传动]

 