摘  要:目的采用不同紫外线辐照仪对相同紫外线灯辐射照度进行监测,分析其存在误差,为医疗单位科学的消毒监测管理提供依据。方法随机抽取4个医疗单位的紫外线辐照仪,分为A、B、C、D组,对某院8个科室25个移动式紫外线灯50根灯管进行辐照度监测,紫外线灯上管采用垂直中间与外端,下管采用水平中间与外端监测,依据GB19258-2012、WS/T367-2012判断紫外线灯的辐照度,采用SPSS18.0进行描述分析。结果A、B、C、D个检测仪器对50个紫外线的检测结果,存在组间差异(F=247.104,P=0.00),其中A组与B组之间差异无统计学意义(P>0.05),A组、B组与C组与D组之间差异存在统计学意义(P=0.00)。4种仪器对紫外线灯的中间检测结果与末端检测结果之间差异存在统计学意义(P=0.00)。结论紫外线辐照仪未进行常规监测与监测人员未按规范要求正确监测是造成本次紫外线灯监测不合格的主要原因。提示基层医疗单位应重视紫外线灯的管理,监督与购入科室应严格把关,严格按规范要求并定期校验及监测,以保证监测效果,为医疗单位提供合格的监测数据,保证消毒质量。object ive To monitor the disinfection effect ofthe same ultraviolet germicidal lamp of ultraviolet Irrandiance luminace with different ultraviolet radiation instrument, analyze the error, and provide the basis for the medical unit scientific disinfection monitoring and management. Methods A random sample of four medical units of ultraviolet irradiation apparatus, divided into A, B, C, D group, irradiance monitoring of a hospital in eight sections of 25 mobile type ultraviolet lamp 50 root tube, ultraviolet lamp pipe with vertical center and the outer end, under the control of the intermediate level and the outer end of the monitoring, according to GB19258-2012, WS/T367-2012 judgment of ultraviolet lamp irradiance using SPSS18.0 were described and analyzed. Results A, B, C, D a detection instrument of 50 ultraviolet detection results(F=247.104,P=0.000), there are differences between the groups, which difference between group A and group B no statistical significance(P〉0.05). The difference between a group and B group and C group and D group are statistically significant(P=0.000).There was a significant difference between the 4 instruments on the detection results of the UV lamp and the results of the end detection(P=0.000).Conclusions The main reason for the failure of the monitoring of the ultraviolet lamp is not to be monitored and monitored by the conventional monitoring and monitoring personnel. It is suggested that the grassroots medical units should attach importance to the management of the ultraviolet lamp, supervision and purchase department should be strict, strict according to the specifications and periodic verification and monitoring, to ensure the effectiveness of monitoring,medical units provide qualified monitoring data, to ensure the quality of disinfection.

关 键 词:紫外线灯 辐照仪 辐照强度 监测 分析 

分 类 号:R187.4[医药卫生—流行病学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象