检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:崔英杰 段坤淼 朱亚波[1] Cui Yingjie;Duan Kunmiao;Zhu Yabo(Harbin Boiler Co., Ltd., Harbin 150046, China)
机构地区:[1]哈尔滨锅炉厂有限责任公司,黑龙江哈尔滨150046
出 处:《锅炉制造》2018年第3期5-9,共5页Boiler Manufacturing
摘 要:炉膛安全监控系统(The Furnace Safeguard Supervisory System,简称FSSS)是现代火电机组必备的监视与保护系统,一般作为独立功能模块(组)集成于机组的DCS系统中。由于燃料的特殊性,燃油燃气锅炉的FSSS系统在逻辑上有其特殊性,不同于常规的燃煤锅炉。以某工程600MW级机组为例来介绍燃油燃气炉中FSSS系统的逻辑设计要点。The Furnace Safeguard Supervisory System (FSSS) is a necessary monitoring and control system for modem thermal power unit, FSSS normally as an independent function module (Group) integrated into the DCS system of the unit. Because of the particularity of fuel, the FSSS system of oil and gas boiler has its particularity in logic, which is different from the conventional coal -fired boiler. Taking an engineering 600MW unit as an example, the logic design points of FSSS system in oil and gas fired furnace are introduced.
关 键 词:FSSS 燃油 天然气 泄漏试验 油枪吹扫 全燃料跳闸(MFT) 负荷管理
分 类 号:TK229[动力工程及工程热物理—动力机械及工程]