双源CT诊断非金属可疑食管异物的队列研究  被引量:4

Cohort study of diagnosis for suspicious non-metal foreign body in esophagus by dual source CT

在线阅读下载全文

作  者:顾潇怡 张茹 朱正华[1] 戴工华 王轶彬[2] 李炜[3] 张宇 马兆鑫[1] 周雁 周珏[1] 陈蔚静[1] GU Xiao-yi;ZHANG Ru;ZHU Zheng-hua;DAI Gong-hua;WANG Yi-bin;LI Wei;ZHANG Yu;MA Zhao-xin;ZHOU-Yan;ZHOU-Yu;CHEN Wei-jing(Department of Otolaryngology;Department of Radiology;Endoscopic Examination Room, Department of Gastroenterology, Shanghai East Hospital, Shanghai 200120, China)

机构地区:[1]上海市东方医院耳鼻咽喉科 [2]上海市东方医院放射科 [3]上海市东方医院消化内科内镜检查室

出  处:《中国耳鼻咽喉颅底外科杂志》2018年第2期159-162,共4页Chinese Journal of Otorhinolaryngology-skull Base Surgery

摘  要:目的通过分析双源CT诊断非金属食管异物的敏感性和特异性,评价双源CT对非金属可疑食管异物的诊断意义。方法应用前瞻性队列研究,选取2015年1月1日~2016年12月31日符合纳入标准的患者153例双源CT和正侧位平片对照。结果 93例双源CT阳性示食管异物,其中57例平片阳性;内镜检查证实并取出92例,内镜检查阴性1例。本组病例中双源CT敏感性100%(92/92),特异性98.4%(60/61),阴性预测值100%(60/60)。结论双源CT检查非金属食管异物敏感性、特异性、阴性预测值高,能明确异物类型及异物位置。双源CT可作为非金属食管异物的常规检查,及时诊断,避免不必要的食管内镜检查。Objective To investigate the diagnostic value of dual source computed tomography(DSCT) for suspicious non-metal foreign body in the esophagus. Methods A prospective study was performed on 153 patients with a history of suspicious non-metal foreign body impaction by comparing their DSCT and anteroposterior and lateral position Xray films. Results Of all the 153 patients,DSCT showed foreign body in 93 cases with positive plain film results in 57.Endoscopic confirmation and removal of esophageal foreign body was achieved in 92 of the 93 patients,and one patient got negative endoscopic examination result. For the diagnosis of esophageal non-metal foreign body,the sensitivity of DSCT was100%(92/92) and the specificity was 98. 4%(60/61) with a negative predictive value of 100%(60/60). Conclusion With high sensitivity,specificity and negative predictive value,DSCT can be applied to identify the type and location of esophageal non-metal foreign body. Therefore,DSCT should be considered as the first-choice diagnostic technique for esophageal non-metal foreign body for expedited diagnosis and avoidance of unnecessary esophagoscopic examination.

关 键 词:双源CT 非金属食管异物 诊断 

分 类 号:R768.32[医药卫生—耳鼻咽喉科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...