作 者:卢颖[1] 黄光亮[1] 郑艳玲[1] 刘保娴 陈勉妮[1] 谢晓燕[1] Lu Ying;Huang Guangliang;Zheng Yanling;Liu Baoxian;Chen Mianni;Xie Xiaoyan(Department of Medical Ultrasonic, Institute of Ultrasonic Diagnosis and Interventional Ultrasound, the First Affiliated Hospital of Sun Yat-sen Uaiversity, Guangzhou 510080, China)
机构地区:[1]中山大学附属第一医院超声科中山大学超声诊断与介入超声研究所,广州510080
出 处:《中华普通外科学文献(电子版)》2018年第2期106-110,共5页Chinese Archives of General Surgery(Electronic Edition)
基 金:国家自然科学基金资助项目(81501493;81530055)
摘 要:目的探讨实时三维超声造影(4D-CEUS)成像质量的影响因素。方法回顾性分析2013年6月至2014年3月经病理及临床确诊的151例肝脏局灶性病变(FLLs)患者的影像资料,对其4D-CEUS成像质量进行评分并分析影响成像质量的因素。结果 (1)4D-CEUS检查时慢推造影剂组得到的纯动脉相最长,平均时间为(5.17±1.03)s,成像质量优于常规团助法(统计值88.868,P=0.000)。(2)151例FLLs的4D-CEUS动脉期成像质量评价1级82例(54.3%),2级17例(11.3%),3级25例(16.6%),4级27例(17.9%)。151例病变呈高、等、低或无增强者分别有119例(78.8%)、6例(4.0%)和26例(17.2%)。病变直径、位置、扫查路径、有无干扰因素、有无伪影、动脉期增强程度对4D-CEUS的成像质量有显著影响(统计值为-2.455、-2.198、-2.428、-5.575、-6.469、43.060,均P<0.05)。结论 4D-CEUS成像质量的影响因素有注药方式,病变直径、位置及增强方式,扫查路径、扫查过程中有无伪影,有无膈肌、肋骨、心脏、大血管等成像干扰因素。Objective To explore 4 D-CEUS methodologies and the factors affecting image quality. Methods 4 D-CEUS data of one hundred and fifty-one focal liver confirmed by pathology and clinical follow-up from the First Affiliated Hospital of Sun Yat-sen University were respectively analyzed. The image quality was scored and influencing factors were analyzed. Results(1) The injection methods of 4 D-CEUS had significant influence on the imaging quality of 4 D-CEUS, while slow injecting contrast agents without saline could prolong pure arterial pulse, mean time was(5.17±1.03) s, with image quality superior to conventional bolus(statistical value 88.868, P=0.000).(2) The image quality of 4 D-CEUS in the arterial phase of 151 FLLs was divided into 4 grades, with 82 cases(54.3%) in grade 1, 17 cases(11.3%)in grade 2, 25 cases(16.6%) in grade 3, 27 cases(17.9%) in grade 4. The number of lesions showing hyper-enhancement, iso-enhancement, hypo-enhancement was 119(78.8%), 6(4.0%) and 26(17.2%), respectively. Location of lesions, sizes, scanning path, interference, and the artifacts had significant influences on the image quality of 4 D-CEUS(statistical values-2.455,-2.198,-2.428,-5.575,-6.469, 43.060, all P0.05). Conclusion The image quality of 4 D-CEUS is affected by the method of injection, sizes of lesions, location, blood supply, scanning path, the presence of artifacts, and the presence of interference.
分 类 号:R445.1[医药卫生—影像医学与核医学] R575[医药卫生—诊断学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222