动态顶空-气相色谱质谱法测定家用搅拌机中苯系物迁移量  被引量:8

Determination of BTEXs Migration Amount in Food Blender by Dynamic Headspace GC-MS

在线阅读下载全文

作  者:彭剑林 王志娟[1] 李海玉[1] 王婉[1] 张庆[1] 白桦[1] 吕庆[1] PENG Jian-lin, WANG Zhi- juan,LI Hai-yu, WANG Wan, ZHANG Qing, BAI Hua, LV Qing(Institute of Industrial and Consumer Product Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, Chin)

机构地区:[1]中国检验检疫科学研究院工业与消费品安全研究所

出  处:《化学试剂》2018年第5期437-441,共5页Chemical Reagents

基  金:国家质检公益性行业科研专项资助项目(201510031)

摘  要:基于动态顶空-气相色谱质谱技术,建立了家用搅拌机中7种苯系物迁移量的测定方法。采用0.8 L(10%)乙醇模拟液在搅拌机正常工作下进行迁移,以动态顶空吹扫捕集进样、气相色谱-质谱联用检测、外标法定量。该方法对7种苯系物的定量限(LOQ)为0.2-0.4μg/L,具有较高的灵敏度,在0.2-20.0μg/L浓度范围内线性关系良好(其中苯的线性浓度范围为0.4-20.0μg/L,7种苯系物的R^2≥0.995 6)。低、中、高3个添加浓度水平的平均回收率在76.7%-123.3%之间,相对标准偏差(RSD,n=6)在2.2%-14.1%之间。最后,将此方法应用于9款实际搅拌机样品的测定。该方法操作简单、快速、环保、灵敏度高,可用于家用搅拌机中苯系物的迁移量检测。A method was developed for the determination of BTEXs migration amount in food blender by dynamic headspace autosampler(DHS-GC-MS).0. 8 L food simulants were added to blender and the migration process was studied under the normal operation,then the migration analytes were determined by DHS-GC-MS and quantified by external standard method. The limits of quantification(LOQ) of the method established were 0. 2 - 0. 4 μg/L for analytes.The linear ranges with good correlation coefficient(R^2≥0. 995 6) were obtained as 0. 4-20. 0 μg/L for benzene and 0. 2-20. 0 μg/L for other analytes.Moreover,the average recoveries of analytes at three added levels ranged from 76. 7% to 123. 3% with RSD(n = 6) varied from 2. 2% to 14. 1% in food simulants.Finally,the method was applied to test nine commercial blenders.In conclusion,the method is simple,rapid,sensitive,environmentally-friendly and suitable for the analysis of BTEXs migration amount in blender.

关 键 词:动态顶空 家用搅拌机 苯系物 迁移量 

分 类 号:O657.63[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象