作 者:颜宏勇 YAN Hongyong(Tus-Design Group Co., Ltd., Suzhou 215021, Jiangsu Province, China)
机构地区:[1]启迪设计集团股份有限公司,江苏省苏州市215021
出 处:《建筑电气》2018年第5期86-88,共3页Building Electricity
摘 要:现行规范要求消防控制室应有消防电源监控器,意味着设置消防控制室的建筑应有消防设备电源监控,消防设备电源监控系统应满足相关规范要求;监控点的设置应在被监控设备的供电末端;消防设备电源监控探测参数应根据被监控消防设备的运行特点确定。According to the current code requirements, a fire control room shall have a power supply monitor for fire fighting, which means that the buildings with fire control rooms shall have the power monitoring systems for fire fighting epuipment, which shall meet the relevant code requirements. The monitory points shall be located at the power supply terminal of the epuipment monitored. The power monitoring and detection parameters for fire fighting epuipment shall be determined according to the running characteristics of the fire fighting epuipment monitored.