摘  要:在复杂的土壤环境中,土壤的电阻率比较大,传统的金属接地极在降低接地电阻方面比较困难。文中通过非金属接地模块与传统金属接地模块对比实验、分析,得出在复杂土壤中非金属接地模块接地电阻值与采用传统金属接地极对比能降低三分之一左右。In complex soil environment,the resistivity of the soil is relatively large.The traditional metal grounding electrode is difficult to reduce the grounding resistance.The comparison experiment and analysis of the non-metal grounding module and the traditional metal grounding module showed that the grounding resistance value of the non-metal grounding module in the complex soil can be reduced by about 1/3 with the comparison of the traditional metal grounding electrode.