差示扫描量热法研究硬聚氯乙烯管材的加工温度  

Study on the Processing Temperature of Rigid PVC Pipes by Differential Scanning Calorimetry Method

在线阅读下载全文

作  者:潘永红 余巧玲 王万卷 刘志健 徐运祺 容腾 魏远芳 陈学亮 PAN Yong-hong;YU Qiao-ling;WANG Wan-juan;LIU Zhi-jian;XU Yun-qi;RONG Teng;WEI Yuan-fang;CHEN Xue-liang(National Center for Quality Supervision and Testing of Polymer Materials and Products, Guangzhou 510110, China;Guangzhou Quality Supervision and Testing Institute, Guangzhou 510110, China)

机构地区:[1]国家高分子工程材料及制品质量监督检验中心,广东广州510110 [2]广州质量监督检测研究院,广东广州510110

出  处:《塑料工业》2018年第6期41-43,共3页China Plastics Industry

摘  要:通过差示扫描量热法(DSC)研究了硬聚氯乙烯(PVC)管材的加工温度(Tp),研究了制样效果,干扰峰,不同取样位置对Tp的影响。结果表明,试样与样品盘越充分接触,得到的DSC曲线呈现的Tp峰越好;管材在生产过程中使用润滑剂聚乙烯(PE)蜡,DSC曲线会在130℃左右出现干扰峰;管壁中心部位的Tp低于管壁内外表面的Tp。The processing temperature of rigid polyvinyl chloride (PVC) pipes was studied by differential scanning calorimetry (DSC). The effect of sample preparation, spurious peak and the different sampling positions were investigated. The results show that the more sufficient contact between the pan and the test piece, the better results of the processing temperature was presented by the DSC curve. With polyethylene (PE) wax used as a lubricant in the pipe formulation, the DSC curve would have a spurious peak at 130℃ approximately; the processing temperature at the centre of the pipe wall is often lower than that close to the inner and outer surface.

关 键 词:差示扫描量热法 硬聚氯乙烯管材 加工温度 制样效果 干扰峰 取样位置 

分 类 号:TQ317.2[化学工程—高聚物工业]

 