作 者:隋美蓉 顾修全[3] 时梅林 刘琳琳 倪中海[1] SUI Mei-Rong;GU Xiu-Quan;SHI Mei-Lin;LIU Lin-Lin;NIZhong-Hai(School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou, Jiangsu 221116, China;College of Medical imaging, Xuzhou Medical University, Xuzhou, Jiangsu 221004, China;School of Materials Science and Engineering, China University of Mining and Technology, Xuzhou, Jiangsu 221116, China)
机构地区:[1]中国矿业大学化工学院,徐州221116 [2]徐州医科大学医学影像学院,徐州221004 [3]中国矿业大学材料科学与工程学院,徐州221116
出 处:《无机化学学报》2018年第6期1183-1191,共9页Chinese Journal of Inorganic Chemistry
基 金:中央高校基本科研业务费专项资金(No.2015XKZD08)资助项目
摘 要:采用旋涂法在FTO(SnO_2∶F)导电玻璃衬底上沉积得到BiVO_4多孔薄膜用以光解水,改变前驱体的浓度和旋涂次数以调控薄膜的厚度。研究了电解液成分、膜层厚度及表面改性等因素对刚经历过退火处理的BiVO_4薄膜光电化学(PEC)性能的影响。结果表明:通过在电解液中添加适量的空穴吞噬剂Na_2SO_3,或对表面进行Co-Pi改性均能有效改善BiVO_4薄膜的PEC活性。这些措施均能有效抑制固液界面处的载流子复合反应。经Co-Pi改性的BiVO_4薄膜在0.6 V(vs SCE)偏压下,0.1 mol·L^(-1) Na_2SO_4+0.1mol·L^(-1)Na_2SO_3的电解液中展现出最高的光电流密度(4.3 m A·cm^(-2))。此外,选用一个代表性BiVO_4薄膜作为光阳极制备了一个PEC生物传感器,在检测谷胱甘肽(GSH)上表现出比较高的灵敏度。本研究证实了BiVO_4薄膜的PEC性能严重依赖着光俘获效率和载流子输运过程。Porous BiVO4 thin films have been prepared on the fluorine doped tin oxide(SnO2∶F) coated glass substrates through a facile spin-coating strategy for water splitting application. The film thickness was tuned by varying the deposition cycles and the precursor concentration, respectively. The influences of electrolyte composition, film thickness and surface modification were investigated on the actual photoelectrochemical(PEC)performance of the as-annealed BiVO4 porous films. The results show that the PEC activity of BiVO4 can be enhanced effectively by adding a hole scavenger Na2SO3 with suitable amount into the electrolyte, or modified the surface with a co-catalyst Co-Pi. These methods can suppress the carrier recombination that occurs at the solid/liquid interface. The highest photocurrent density(4.3 m A·cm-2 at a bias of 0.6 V(vs SCE)) was achieved in the BiVO4 samples which were synthesized at the optimal condition and characterized under a visible-light irradiation intensity of 100 mW·cm-2, using a 0.1 mol·L-1 Na2 SO4+0.1 mol·L-1 Na2SO3 electrolyte. Additionally, a facile PEC bio-sensor is constructed by using a BiVO4 film anode, leading to an acceptable sensitivity for detecting the glutathione(GSH). In a word, it is demonstrated that the PEC performance of BiVO4 is dependent on both the light harvesting and carrier diffusion process.
分 类 号:TB34[一般工业技术—材料科学与工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117