检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王杰 胡兆燕[1,2] 陈正龙 王维念 WANG Jie;HU Zhaoyan;CHEN Zhenglong;WANG Weinian(School of Medical Instrunwnt and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093;School of Medical Instrunwntation, Shanghai University of Medicine and Health Sciences 201318;Mechanical Engineering College, University of Shanghai for Science and Technology, Shanghai 200093)
机构地区:[1]上海理工大学医疗器械学院,上海200093 [2]上海健康医学院医疗器械学院,上海201318 [3]上海理工大学机械学院,上海200093
出 处:《北京生物医学工程》2018年第3期291-296,共6页Beijing Biomedical Engineering
摘 要:目的跌倒对老年人身心健康有着巨大威胁。针对现存跌倒防护装置结构复杂且充气方式不安全等问题,设计一套基于检测跌倒能自动充气的机械装置,以帮助老人在意外跌倒时能够通过气囊充气防护免受伤害。方法该保护装置由压缩二氧化碳气瓶、充气机构和保护气囊3部分组成,首先防护模块以CO_2为充气源,传动机构采用大功率舵机带动同轴的凸轮旋转,随着凸轮旋转刺针直线运动刺破气瓶;然后采用拉伸机对刺针刺破钢瓶力度进行测试,进而通过最大刺穿力和凸轮推程选定合适扭矩舵机;最后利用气体动力学等熵流公式预测气囊充气时间。结果对身高在163~174 cm的学生进行测试,模仿老人步态分别进行向前、向后和侧面跌倒实验,测得3种方式跌倒的时间分别为(865±41.49)ms、(788±53.56)ms和(852±65.37)ms;同时通过模拟气囊充气过程,获得气囊充气时间为(441±29.6)ms。将实验获得的跌倒时间和气囊充气时间进行对比可知,在老人跌倒过程中有较为充裕的时间为气囊充气,验证了利用压缩二氧化碳对气囊充气实现跌倒保护的可行性。结论本跌倒防护装置在跌倒检测的基础上,能够实现跌倒防护、减少跌倒带来的伤害,且装置具有结构简单、可靠性高、价格低廉等优点,适宜于推广应用。Objective Falling is a great threat to the physical and mental health of the elderly. In view of the problems about the complicated structure of the existing fall protection device and the unsafe way to inflate the gas,this paper designs a mechanical device based on detecting and tripping inflate automatically,which can help the elderly avoid injuring by the air bag inflatable protection when they accidentally fall.Methods The protective device was composed of a compressed carbon dioxide gas cylinder,an inflatable mechanism and a protective airbag. Firstly,the protective module used CO2 as aeration source,and the transmission mechanism used a high-power steering gear to drive the rotation of the coaxial cam. With the cam rotating,the puncture needle with linear motion punctured the gas cylinder. Secondly,The tensile machine was used to test the puncture needle 's strength of piercing cylinder,and then selected the appropriate torque servoaccording to the maximum piercing force and the cam drive. Finally,the gas-kinetic isentropic flow formula was used to predict the airbag inflation time. Results The students whose height was between 163 cm and 174 cm were tested to imitate the gait of the elderly about performing forward,backward and side fall tests respectively,and measured these three ways to fall in the time of(865±41. 49) ms,(788±53. 56) ms,and(852 ± 65. 37)ms respectively; simultaneously,the air balloon inflation was(441± 29. 6) ms by simulating the airbag inflation process. Comparing the fall time obtained by the experiment with the inflating time of the airbag,we know that there was ample time for the airbag to inflate during the fall of the elderly,and verified the feasibility of using compressed carbon dioxide to realize the fall protection with the airbag inflation. Conclusions The fall protection device based on the fall detection can achieve the fall protection and reduce the damage caused by the fall. The device has the advantages of simple structure,high reliability and low pr
分 类 号:R318.04[医药卫生—生物医学工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145