检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李青[1] 刘红光[1] 李凌梅[1] 张欣[1] 路瑞军[1] Li Qing;Liu Hongguang;Li Lingmei;Zhang Xin;Lu Ruijun(Tianjin Scientific Research Institute of Metrology Supervision and Inspection,Tianjin 300192,China)
机构地区:[1]天津市计量监督检测科学研究院
出 处:《国外电子测量技术》2018年第6期35-38,共4页Foreign Electronic Measurement Technology
摘 要:为保障三坐标测量机测量结果的准确度和可信度,对三坐标测量机校准综合示值误差进行了分析。依据JJF1064-2010《三坐标测量机》校准规范,选取经校验的量块作为主标准器校准三坐标测量机,阐述了标准器测量模型基本原理及测量过程中方位及尺寸要求,依据测量模型,建立测量不确定度评定模型,根据GUM法获得各个主要误差源的传递因数,分析计算各不确定度分量,最终得到扩展标准不确定度U=(0.20+1.95L/1000)μm,k=2。In order to ensure the accuracy and reliability of the measurement results of the three coordinate measuring machine,this paper analyzed the calibration comprehensive indication error of the three coordinate measuring machine.The calibrated gauge was selected to calibrate three coordinate measuring on the basis of " JJF1064-2010" three coordinate measuring machine calibration specification.This paper introduced the basic principle of standard measurement model,range and size requirements in the measurement process,build the model of measurement uncertainty evaluation,obtained the transfer factor of the main error sources based on the GUM method,calculated the component of each uncertainty.Finally get extension standard uncertainty U=(0.20+1.95 L/1000)μm,k=2.
分 类 号:TH711[机械工程—测试计量技术及仪器] TN06[机械工程—仪器科学与技术]