检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘志强 马燕[2] 刘志勇[2] 高晶 LIU Zhi-qiang;MA Yan;LIU Zhi-yong;GAO Jing(Rocket Force University of Engineering,Xi'an 710025,China;Northwest institute of nuclear technology,Xi'an 710024,China)
机构地区:[1]火箭军工程大学,西安710025 [2]西北核技术研究所,西安710024
出 处:《核电子学与探测技术》2018年第1期123-126,共4页Nuclear Electronics & Detection Technology
基 金:国家自然科学基金(11405267)资助
摘 要:为提高检测宽量程剂量仪的效率,提出了对宽量程剂量仪进行批量检测的方法。该方法一次将多个宽量程剂量仪放入强源源室内,然后通过软件逐个检测剂量仪,从源室外显示结果是否稳定判断剂量仪是否存在故障。理论分析与实验结果均表明,采用这种方法对宽量程剂量仪进行检测,可大大提高检测效率。A method of batch detection for wide range dosimeter is proposed in this paper. Firstly, a batch wide range dosimeters are put into a strong source chamber at one time. Secondly, the dosimeters are detected by software one by one. Finally,judging the stabihty of the result from the outside of the source to determine whether there is a fault in the dosimeter. Theoretical analysis and experimental results show that this method can improve the detection efficiency greatly.
分 类 号:TL811[核科学技术—核技术及应用]