作  者:杨久春 李正强 李凯涛 李保生 李东辉 YANG Jiuchun;LI Zhengqiang;LI Kaitao;LI Baosheng;LI Donghui(State Environmental Protection Key Laboratory of Satellite Remote Sensing,Institute of Remote Sensing and Digital Earth,Chinese Academy of Sciences,Beijing 100101,China;Hefei University of Technology,Hefei 230009,China)

机构地区:[1]中国科学院遥感与数字地球研究所国家环境保护卫星遥感重点实验室,北京100101 [2]合肥工业大学,安徽合肥230009

出  处:《大气与环境光学学报》2018年第4期293-303,共11页Journal of Atmospheric and Environmental Optics

基  金:中国科学院STS项目;国家自然科学基金;41701405;41401423;41501390~~

摘  要:太阳辐射计是观测大气气溶胶重要的地基遥感设备,其定标是获取高精度气溶胶产品的前提条件.视场角(field of view,FOV)是太阳辐射计的重要参数,也是传递定标的关键参数.基于SONET观测网2016年定标实验,对传递定标方法(单次传递及历史传递平均结果)和矩阵扫描法获得的仪器FOV进行对比分析,结果表明:单次传递、历史传递平均和激光矩阵扫描结果与仪器的FOV设计值平均相对误差在2%~3%之内,而三种方法获得的FOV最大相对误差为1.59%,满足FOV的精度要求。误差分析表明,传递定标法误差主要来自积分球辐亮度定标系数,而矩阵扫描法的误差主要由激光面光源引起。但三种方法各有优劣,可以相互验证、相互补充,以获得更加准确的仪器FOV参数。Sun radiometer is an important ground-based remote sensing device to observe atmospheric aerosol,and the calibration is a prerequisite to obtain the high accuracy of aerosol products. Field of view(FOV) is an important parameter of sun radiometer, and it is also a key parameter for the transfer calibration. Based on the calibration experiment of Sun-sky radiometer observation network(SONET) in 2016, the FOV of instruments obtained by transfer method(single transfer and the average result of historical transfer) and matrix scanning method were analyzed, and the result showed that the average relative error of the results obtained by single transfer, the average of historical transfer and the matrix scanning is within 2%~3%, and the max average relative error is 1.59% compared with themselves. The three methods can satisfy the requirements of the precision of FOV. The error analysis shows that the error of transfer calibration method mainly comes from integrating sphere radiance calibration coefficient, and the error of matrix scanning method is mainly caused by the laser beam. However, these three methods all have their own advantages and disadvantages. They can verify and complement each other, in order to obtain more accurate FOV of the instrument.

关 键 词:太阳辐射计 对比定标 视场角 传递定标 矩阵扫描 

分 类 号:TH753[机械工程—仪器科学与技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象