作 者:肖明 李绚绚 傅国斌 马勇飞 张杰 XIAO Ming;LI Xuan-xuan;FU Guo-bin;MA Yong-fei;ZHANG-jie(Qinghai Electric Power Research Institute,Xining 810000,China;Institute of Economic and Technical Research of Qinghai Electric Power Company,Xining 810000,China)
机构地区:[1]国网青海省电力公司电力科学研究院,青海西宁810000 [2]国网青海省电力公司经济技术研究院,青海西宁810000
出 处:《电气开关》2018年第3期83-85,88,共4页Electric Switchgear
摘 要:分析了励磁调节器励磁调节不当引起电力系统产生低频振荡的原因,然后阐述了电力系统稳定器(PSS)抑制低频振荡的原理;介绍了某水轮发电机组PSS参数试验步骤,验证PSS抑制低频振荡的效果,进而证实了PSS参数整定的正确性。The reason of low frequency oscillation in power system caused by improper excitation regulation is analyzed,then the principle of power system stabilizer( PSS) to suppress low frequency oscillation is described; In this paper,the test procedure of PSS parameters for a hydroelectric generating set is introduced and the effect of PSS to suppress the low frequency oscillation is verified,which confirms the correctness of PSS parameter setting.
关 键 词:低频振荡 电力系统稳定器 水轮发电机组 PSS参数整定
分 类 号:TM71[电气工程—电力系统及自动化]