检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:曹艳平[1] 姜大峰[1] 李凤华[1] 陈金东[1] 李蔚[1] 焦燕妮[1] CAO Yanping, JIANG Dafeng, LI Fenghua, CHEN Jindong, LI Wei, JIAO Yanni(Shandong Center for Disease Control and Prevention, Jinan 250014, Chin)
机构地区:[1]山东省疾病预防控制中心,山东济南250014
出 处:《色谱》2018年第7期685-692,共8页Chinese Journal of Chromatography
基 金:山东省医药卫生科技发展计划项目(2014WS0382)~~
摘 要:建立了一种气相色谱-三重四极杆质谱结合双稳定性同位素内标检测鱼样中多氯联苯的方法。采用自动索氏提取器提取样品中的多氯联苯,经一根复合净化柱净化后,采用质谱多反应监测模式检测,选取两个独立的离子对。分析了20种多氯联苯,包含7种指示性多氯联苯,从三氯联苯到八氯联苯每族3个化合物,九氯联苯和十氯联苯各一个,每族使用一个相同氯代程度的^(13)C12标记多氯联苯作为定量内标、2种回收内标。20种多氯联苯在33min内流出,分离良好,线性范围为0.05~10μg/L,相关系数r均在0.99以上,低、中、高3种水平的加标回收率均在80.3%~117.6%之间,相对标准偏差(RSD,n=6)在5.09%~18.5%之间,方法检出限为0.01~0.02μg/kg。20种多氯联苯总量在1.2~8.8μg/kg(湿重)范围内,7个指示性多氯联苯总量在0.68~6.4μg/kg(湿重)范围内。该方法缩短了分析时间,减少了有机溶剂的使用量,适合鱼样中多氯联苯的测定。An improved method based on the isotope dilution technique was developed for the determination of 20 polychlorinated biphenyls(PCBs) in fish samples,including seven indicator polychlorinated biphenyls. The analysis was performed by gas chromatography-triple-quadrupole mass spectrometry(GCMS/MS) in the multiple reaction monitoring(MRM) mode. Two MRM transitions were monitored for each PCB congener for quantitation and qualification purposes. The edible parts of the fish samples were shattered,frozen,and dried. -(13)C-PCB surrogate standards were spiked into the fish samples. The PCBs in fish samples and the surrogate standards were extracted by auto-Soxhlet extraction. The extract was cleaned-up by a disposable multi-layer column packed with acidic silica gel and basic alumina. -(13)C-PCB recovery standards were spiked into the extract before injection. The separation was performed on a TG-5 MS capillary column. Quantitation was performed by the internal standard method. Every group of PCBs used a same number chlorinated -(13)C-isotope PCBs congener as the internal standard. The calibration curves of 20 PCB congeners were linear(correlation coefficient(r) 0. 99) within the range of 0. 05-10μg/L. For the recovery test,three levels were spiked in matrices. The average recoveries obtained by this method were 80. 3%-117. 6% and the relative standard deviations(RSDs,n = 6) were 5. 09%-18. 5%.The limits of determination(LODs) were 0. 01-0. 02 μg/kg. Contents of the 20 PCBs in the fish sampleswere in the range 1. 2-8. 8 μg/kg(wet weight),while those of the seven indicator PCBs were in the range 0. 68-6. 4 μg/kg(wet weight). The method is suitable for determining polychlorinated biphenyls in fish samples.
关 键 词:气相色谱-三重四极杆质谱 同位素内标 多氯联苯 鱼样
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30