检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:甄德印 ZHEN Deyin(China Railway,Enginnering quality and Satety Supervision Bureau,Beijing 100844,China)
机构地区:[1]中国铁路总公司工程质量安全监督局,北京100844
出 处:《铁道机车车辆》2018年第3期83-85,88,共4页Railway Locomotive & Car
摘 要:介绍了一起接触网隔离开关绝缘子污闪造成电动操作机构、远动控制箱等设备烧损的事故。为了分析烧损原因,笔者分析了绝缘子污闪过程和电弧特性,对污闪电弧稳态时段操作机构电位提升进行了计算,在此基础上对操作机构等设备进行分析,找到了烧损原因。接地电流引发操作机构电位发生较大抬升,造成操作机构箱内绝缘反向击穿是设备烧损的直接原因。笔者根据原因分析,针对性的提出防范措施,部分措施已经被采取,收到良好效果。This paper introduces an accident of electrical operation mechanism,remote control box,etc.,which is caused by the insulator pollution flashover.To analyze the rootcause of burning,the author analyzes the process of insulator pollution flashover and the arc characteristics,The potential improvement of operating mechanism in the steady state time of the fouling lightning arc is calculated.On this basis,the operation mechanism and other equipment are analyzed,then found the cause of the burn.The discharge current caused by the insulator pollution flashover caused a great uplift of the operating mechanism,it causes the reverse breakdown of insulation in the cabinet,and this is the direct cause of equipment burn.Based on the analysis,the author puts forward the target preventive measures,which had been adopted and produced effective results.
分 类 号:U225.3[交通运输工程—道路与铁道工程]