肿块与非肿块型乳腺癌病灶扩散加权成像参数的重复性与一致性研究  被引量:16

Repeatability and consistency of diffusion-weighted imaging parameters for breast cancer with mass and non-mass

在线阅读下载全文

作  者:王梦茹 刘万花[1] 王瑞[1] 叶媛媛[1] 张悦 Wang Mengru;Liu Wanhua;Wang Rui;Ye Yuanyuan;Zhang Yue(Department of Radiology,Zhongda Hospital,Southeast University,Nanjing 210009,China)

机构地区:[1]东南大学附属中大医院放射科,南京210009

出  处:《中华放射学杂志》2018年第8期598-602,共5页Chinese Journal of Radiology

基  金:国家重点基础研究发展计划(2014CB744504)

摘  要:目的 探讨肿块与非肿块型乳腺癌病变采用不同b值行DWI检查,不同操作者间的重复性和一致性.方法 回顾性分析东南大学附属中大医院2010年12月至2017年10月经乳腺动态对比增强MRI(DCE-MRI)检查发现为乳腺非囊性病灶,行乳腺DWI检查,且经外科手术病理证实为乳腺癌的131例女性患者(133个病灶).肿块型病变94例(96个病灶),非肿块型病变37例(37个病灶).所有患者术前均行乳腺DWI检查,80个病灶测量采用4个b值(0、400、800、1000 s/mm2),其中肿块型病灶有51个,非肿块型病灶29个;53个病灶测量采用5个b值(0、400、800、1200、1600 s/mm2),其中肿块型病灶45个,非肿块型病灶8个.由2名同等资历的放射科医师采用双盲法阅片,分别测量ADC值.采用配对t检验比较2名医师测量参数的差异,采用组内相关系数(ICC)和Cronbachα系数评价2名医师测量的重复性,采用Bland-Altman一致性分析方法评价2名医师间的一致性.结果 不同b值(0、400、800、1200、1600 s/mm2)下乳腺非肿块型和肿块型病变的ADC值,2名医师间测量结果的差异均无统计学意义(P均〉0.05).2名医师测得的不同b值下乳腺非肿块型病变的ADC值ICC分别为0.72、0.78、0.87、0.76、0.74,重复性为好或非常好;Cronbachα值分别为0.83、0.88、0.93、0.86、0.85,信度高.2名医师测得的不同b值下乳腺肿块型病变的ADC值ICC分别为0.88、0.95、0.97、0.93、0.91,重复性非常好;Cronbachα值分别为0.94、0.97、0.99、0.96、0.95,信度高.Bland-Altman图像分析结果显示不同操作者在不同b值下测得的乳腺非肿块型、肿块型病变的ADC值一致性均较好.乳腺非肿块型病变在不同b值下,分别有97.3%(36/37)、94.6%(35/37)、93.1%(27/29)、8/8、8/8的点在95%一致性界限内;乳腺肿块型病变在不同b值下,分别有97.9%(94/96)、94.8%(91/96)、92.2%(47/51)、95.6%(43/45)、93.3%(42/45)Objective To study the repeatability and consistency among different operators while different b-value DW1 was used to detect mass and non-mass breast lesions. Methods Between December 2010 and October 2017, we collected 131 female patients (one hundred and thirty-three lesions) from Zhongda Hospital Southeast University, they were diagnosed as non-cystic lesion of the mammary gland by contrast enhancement MRI (DCE-MRI),were examined with DWI and confirmed by surgical pathology. There were 94 cases of mass lesion (96 lesions) and 37 cases of non-mass lesion (37 lesions). All patients were examined with DWI before surgery,80 patients were examined with b-value of 0, 400, 800 and 1 000 s/mm2, there were 51 tumor lesions and 29 non-tumor lesions;53 patients were examined with b-value of 0, 400, 800 and 1 200,1 600 s/mm2,there were 45 tumor lesions and 8 non-tumor lesions. Two radiologists with the same qualifications used double-blind reading to measure ADC values. Paired t test was used to compare the differences in measurement parameters between the two physicians. The repeatability of data between the two physicians was analyzed by intraclass correlation coefficient (ICC) and Cronbach α coefficients. The consistency of data between the two physicians was evaluated by Bland-Altman analysis. Results In different b values (0,400,800,1 200,1 600 s/mm2), the ADC value of non-mass type breast cancer and mass type breast cancer was no statistically significance between the two operators (P〉0.05).The ICC of the ADC values of the non-mass breast lesion under the different b values measured by 2 physicians were 0.72, 0.78, 0.87, 0.76, 0.74, and the repeatability was good or very good; The Cronbach α coefficients are 0.83, 0.88, 0.93, 0.86, 0.85, and the reliability is high. The ICC of the ADC values of the mass breast lesion under the different b values measured by 2 physicians were 0.88,0.95,0.97,0.93,0.91, and the repeatability was very good. the Cronbach α coefficients were 0.94,0.97,0.9

关 键 词:乳腺肿瘤 磁共振成像 重复性 一致性 

分 类 号:R445.2[医药卫生—影像医学与核医学] R737.9[医药卫生—诊断学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象