BLADE技术在自由呼吸导航CMRT2WI中的应用价值  被引量:4

The value of BLADE technique applied in free-breathing respiratory navigated CMR T2-weighted imaging

在线阅读下载全文

作  者:刘京京 陈铟铟 恽虹 杨姗 曾蒙苏 金航 LIU Jingjing;CHEN Yinyin;YUN Hong;YANG Shan;ZENG Mengsu;J IN Hang(Department of Radiology,Zhongshan Hospital,Fudan University,Shanghai Institute of Medical Imaging,Shanghai 200032,China;Department of Medical Imaging,Shanghai Medical College,Fudan University,Shanghai 200032,China)

机构地区:[1]复旦大学附属中山医院放射科上海市影像医学研究所,上海200032 [2]复旦大学上海医学院影像学系,上海200032

出  处:《实用放射学杂志》2018年第8期1259-1262,共4页Journal of Practical Radiology

基  金:国家自然科学基金项目(81201070).

摘  要:目的探讨刀锋技术(BLADE技术)在自由呼吸导航心脏磁共振(CMR)T2WI中的应用价值。方法对27例患者分别进行自由呼吸导航CMRBLADE-T2WI及常规TSE—T2WI扫描,记录扫描时间,测量图像信噪比(SNR)、心肌血池对比噪声比(CNR)及心脏边缘锐利度,采用配对t检验统计分析。由2位有经验的放射科医师对图像的整体质量、心脏结构显示进行4分度评分,评分结果采用Wilcoxom符号秩和检验统计分析。结果2种方法的扫描时间无统计学显著性差异[BLADE/TSE,(101.07±13.41)s/(95.04±13.29)S,P〉0.05];BLADE—T2WI序列的SNR与CNR(121.23±44.34/107.38±43.17)与TSE-T2WI的SNR与CNR(116.83±40.22/99.23±39.20)相比,差异无统计学意义(P〉0.05);BLADE-T2WI序列的心脏边缘锐利度值高于传统的TSE-T2WI,分别为0.43±0.11,0.31±0.90,差异有统计学意义(P〈0.05)。BLADE—T2WI序列的整体图像质量及心脏结构显示评分均高于TSE-T2WI序列(P〈0.05)。结论BLADE技术有助于提高自由呼吸导航CMR T2WI序列的图像质量,可应用于屏气效果差及自由呼吸导航常规TSE—T2WI图像欠佳的患者。Objective To investigate the value of BLADE technique applied in free-breathing respiratory navigated cardiac magnetic resonance (CMR) T2-weighted imaging.Methods 27 patients underwent free-breathing respiratory navigated BLADE-T2WI and conventional TSE-T2WI respectively.The data acquisition time was recorded for both the methods. The signal to noise ratio (SNR), contrast to noise ratio (CNR) between myocardium and blood pool, and the sharpness of heart edge were measured quantitatively and compared using the paired t-test statistically.The overall imaging quality and the visualization of heart structure were evaluated by two experienced radiologists using a 4-point scale and the results were analyzed statistically using the Wilcoxon signed-ranks test. Results No significant difference was found between the data acquisition time of the two methods [-BLADE/TSE, (101.07 ± 13.41) s/( 95.04 ± 13.29) s, P 〉0.05]. The SNR and CNR of BLADE-T2 WI were similar to those of the TSE-T2WI (121.23±44.34/116.83±40.22, 107.38±43.17/ 99.23 ± 39.20;P〉0.05 for both).BLADE-T2 WI was superior to conventional TSE-T2WI in term of the sharpness of the heart edge (0.43±0.11/0.31 ± 0.90, P 〈0.05 ). The overall imaging quality and the display of heart structure of BLADE-T2 WI were significantly higher than those of TSE-T2WI (P(0.05).Conclusion BLADE is useful for improving the image quality of the free-breathing respiratory navigated CMR T2 WI.h can be applied to patients who can't hold their breath well or have obvious artifacts in conventional free-breathing CMR T2WI.

关 键 词:心脏磁共振 刀锋技术 自由呼吸 T2加权成像 

分 类 号:R445.2[医药卫生—影像医学与核医学] R541[医药卫生—诊断学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象