检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Bo Gao Yong-Bin Leng Han-Jiao Chen Jie Chen Kai-Rong Ye
机构地区:[1]Shanghai Institute of Applied Physics,Chinese Academy of Sciences,Shanghai 201800,China [2]University of Chinese Academy of Sciences,Beijing 100049,China
出 处:《Nuclear Science and Techniques》2018年第8期170-178,共9页核技术(英文)
基 金:supported by the National Science Foundation of China(No.11375255)
摘 要:An X-ray pinhole camera has been used to determine the transverse beam size and emittance on the diagnostic beam line of the storage ring at SSRF since2009.The performance of the beam size measurement is determined by the width of the point spread function of the X-ray pinhole camera.Beam-based calibration was carried in 2012 out by varying the beam size at the source point and measuring the image size.However,this calibration method requires special beam conditions.In order to overcome this limitation,the pinhole camera was upgraded and an X-ray quasi-monochromator was installed.A novel experimental method was introduced by combining the pinhole camera with the monochromator to calibrate the point spread function.The point spread function can be accurately resolved by adjusting the angle of the monochromator and measuring the image size.The X-ray spectrum can also be obtained.In this work,the X-ray quasi-monochromator and the novel beam-based calibration method will be presented in detail.An X-ray pinhole camera has been used to determine the transverse beam size and emittance on the diagnostic beam line of the storage ring at SSRF since2009.The performance of the beam size measurement is determined by the width of the point spread function of the X-ray pinhole camera.Beam-based calibration was carried in 2012 out by varying the beam size at the source point and measuring the image size.However,this calibration method requires special beam conditions.In order to overcome this limitation,the pinhole camera was upgraded and an X-ray quasi-monochromator was installed.A novel experimental method was introduced by combining the pinhole camera with the monochromator to calibrate the point spread function.The point spread function can be accurately resolved by adjusting the angle of the monochromator and measuring the image size.The X-ray spectrum can also be obtained.In this work,the X-ray quasi-monochromator and the novel beam-based calibration method will be presented in detail.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.219.89.207