作 者:薛美 Xue Mei(State Grid Shanxi Electric Power Company Yulin Power Supply Company,Yulin 719000,China)
机构地区:[1]国网陕西省电力公司榆林供电公司,陕西榆林719000
出 处:《环境科学与管理》2018年第6期126-130,共5页Environmental Science and Management
摘 要:传统监测电网绝缘子污染系统存在误差大、精准度低、效果差等问题,不利于排除电网运行隐患,无法保证系统高效监测,影响电网变电站、线路的专业化状态检修。为此提出基于空气质量的电网绝缘子污染监测系统设计。根据污染监测系统整体结构,对系统硬件模块设计,并对泄漏电流采集装置和电流转换电路进行设置,有效监测电网绝缘子污染,实现电网变电站、线路状态检修;基于空气质量监测参数,设计软件数据通信协议和按钮界面。Traditional monitoring system insulators pollution system has many problems,such as large error,low accuracy and poor effect. It is not conducive to exclude the hidden danger of power grid operation. It can not guarantee the efficient monitoring of the system,and affect the specialized condition based maintenance of substation and line. Therefore,the air quality based pollution monitoring system of the power grid is designed. According to the overall structure of pollution monitoring system,design of system hardware,and the leakage current acquisition device and current conversion circuit set,effective monitoring network insulator pollution,implementation of power substation,line state maintenance; air quality monitoring parameters based on the design software of data communication protocol and interface button.