利用橡胶加热带检测钢管混凝土密实度的试验研究  被引量:5

Study on the Detection of the Compactness of Concrete Filled Steel Tube with the Rubber Heating Band

在线阅读下载全文

作  者:王文元 王桂玲[1] 危鼎[1] 杨鸿玉[2] 

机构地区:[1]中国建筑第八工程局有限公司,上海200122 [2]上海理工大学环境与建筑学院,200093

出  处:《混凝土与水泥制品》2018年第8期74-77,共4页China Concrete and Cement Products

摘  要:基于红外热成像技术,利用橡胶加热带对设有缺陷的钢管混凝土柱进行加热,在缺陷区域钢管壁形成温度差,探索利用橡胶加热带检测钢管混凝土密实性。利用ANSYS有限元分析软件,对加热时间、加热温度、缺陷尺寸大小进行模拟分析,结果表明,利用加热带加热的方法可以清晰的辨别出100 mm×100 mm×10 mm(5 mm)的大缺陷,以及50 mm×50 mm×10 mm(5 mm)的小缺陷。Based on the thermal imaging technology, the rubber heater band is used to heat the steel pipe concrete column with defects, and then the temperature difference is formed at defect oreas. The detecting on compactness of concrete filled steel tube is studied. The ANSYS is used to simulate the heating time, heating temperature, defect size. The results show that the use of heating belt can clearly distinguish 100 mm×100 mm×10 mm(5 ram) of the defect, and 50 mm× 50 mm×10 mm(5 mm) of small defects.

关 键 词:钢管混凝土 密实度 检测 橡胶加热带 红外热成像技术 ANSYS 

分 类 号:TU528[建筑科学—建筑技术科学]

 