水泵轴承的失效分析  被引量:3

Failure analysis of water-pump bearing

在线阅读下载全文

作  者:陈义[1] CHEN Yi(State Key Laboratory of Vanadium and Titanium Resources Comprehensive Utilization,Pangang Group Research Institute Co.,Ltd.,Panzhihua 617000,China)

机构地区:[1]攀钢集团研究院有限公司钒钛资源综合利用国家重点实验室

出  处:《物理测试》2018年第4期38-41,共4页Physics Examination and Testing

摘  要:某水泵轴承在使用中发出异常噪音和振动,拆卸检验发现内套圈滚道一端有焊合的堆积金属层,保持架已严重磨损和弯曲变形。检验分析表明,轴承内、外套圈不正,造成保持架磨损,其磨屑进入轴承接触面,进而产生噪声和振动。During the use of a water-pump angular-contact bearing,abnormal noise and vibration had occurred. After it was dismantled and examined,it was found that the built-up metal layers were welded on inner-ring raceway at one end,and a cage was severely worn and bent out of shape. A complete failure analysis of the bearing indicated that the inner or outer rings out of square caused the cage destructive wear,and the wear debris was embedded in the contact surfaces of bearing,which resulted in the noise and vibration.

关 键 词:轴承 磨损 噪声和振动 

分 类 号:TG115[金属学及工艺—物理冶金]

 