水电站调节保证计算工况的选取  被引量:5

Selection of Operating Conditions for Regulating Guarantee Calculation of Hydropower Station

在线阅读下载全文

作  者:刘春燕 韩伶俐[2] LIU Chunyan1, HAN Lingli2(1. Guangxi Water and Power Design Institute, Nanning 530023, Guangxi , China; 2. China Renewable Energy Engineering Institute, Beijing 100120, China)

机构地区:[1]广西壮族自治区水利电力勘测设计研究院,广西南宁530023 [2]水电水利规划设计总院,北京100120

出  处:《水力发电》2018年第9期59-63,共5页Water Power

摘  要:由于调节保证设计涉及多专业,计算边界条件复杂多变,因此调节保证计算工况的选择难度较大。根据水工建筑物、压力钢管结构设计和水轮机设计对调节保证计算的要求,提出了调节保证计算工况的选择方法。The regulating guarantee design of hydropower station involves multiple specialties, and the boundary conditions of calculation are complicated and changeable, which results much difficulties to select the operating conditions for regulating guarantee calculation. The selection methods are put forward herein for regulating guarantee calculation of hydropower station according to the requirements of hydraulic structure, penstock structural design and turbine design on regulating guarantee calculation.

关 键 词:调节保证 工况 水轮发电机组 设计 水电站 

分 类 号:TV131[水利工程—水力学及河流动力学]

 