检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:林晓毅 Lin Xiaoyi(SINOPEC Shanghai Engineering Co.,Ltd,Shanghai 200120)
出 处:《化工与医药工程》2018年第4期50-53,共4页Chemical and Pharmaceutical Engineering
摘 要:针对现在石油化工装置布置紧凑、设计周期短等要求,标准节流式差压流量计直管段要求无法得到满足的问题非常突出。以孔板为例,比较分析了几种常用节流式差压流量计的结构、精度,着重分析对安装直管段的要求,从而提出了在紧凑型化工装置中较适宜的流量计选型。With respect to some requirements existed in petrochemical industry, such as compact structure and short period in design, the problem that standard differential pressure flow-meter cannot reach these requirements is prominent. In this article, exampled with orifice plate, several commonly used orifice differential pressure flow-meters were analyzed and compared in stricture and precision, and the requirement for installation of straight segment was emphatically analyzed, so that the appropriate flow-meter used in compact chemical construction was presented.
关 键 词:紧凑型 直管段要求 标准孔板 多孔孔板流量计 平衡流量计
分 类 号:TH71[机械工程—测试计量技术及仪器]