检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:聂金峰 饶宏 周保荣 李鸿鑫 NIE Jinfeng;RAO Hong;ZHOU Baorong;LI Hongxin(State Key Laboratory of HVDC(Electric Power Research Institute,China Southern Power Grid),Guangzhou 510530,Guangdong Province,China)
机构地区:[1]直流输电技术国家重点实验室(南方电网科学研究院有限责任公司)
出 处:《电网技术》2018年第9期2885-2891,共7页Power System Technology
基 金:国家重点研发计划项目(2016YFB0901001)~~
摘 要:在深入分析现有220k V电网典型接线型式的基础上,提出了可改善接入点近区电网网架结构的柔性直流分极接入220k V电网的典型模式,并以某直流改造工程为例进行了仿真验证。仿真结果表明,文中提出的典型模式优化了柔性直流落点近区的网架结构,改善了电网潮流分布,降低了输电损耗,提高了电网的电压稳定水平。Based on deep analysis of typical connection mode of existing 220 k V power grid, a novel mode of VSC-HVDC separating pole connection with 220 k V power grid was proposed to optimize structure of the grid near receiving terminal converter station. Then, taking system connection schemes of a HVDC transmission system as examples, simulations were carried out. Simulation results proved that the proposed connection mode optimized grid structure, improved power flow distribution and voltage stability, and reduced transmission loss.
分 类 号:TM721.1[电气工程—电力系统及自动化]