1000MW汽轮机低压缸动静轴向磨损原因分析及处理  

Cause Analysis and Treatment on Axial Rubbing Fault between Rotor and Stator in LP Cylinder of a 1000MW Steam Turbine

在线阅读下载全文

作  者:张世伟 胥建群[2] Zhang Shiwei;Xu Jianqun(Guodian Taizhou Power Generation Co. , Ltd. , Taizhou 225300, Jiangsu Province, China;Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education,Southeast University, Nanjing 210096, China)

机构地区:[1]国电泰州发电有限公司,江苏泰州225300 [2]东南大学能源热转换及其过程测控教育部重点实验室,南京210096

出  处:《发电设备》2018年第5期379-382,共4页Power Equipment

摘  要:针对某1 000MW汽轮机组发生的动静部分轴向磨损事故,结合低压差胀锥面测量法,对该机组低压转子调端出汽侧动静部分取样后进行详细的分析,并采取了相应的处理方案及后续运行预防措施。结果表明:所提方案具有较好效果和工程应用价值。To deal with the axial rubbing fault occurring between stator and rotor of a 1 000 MW steam turbine unit, a wear analysis was conducted by taking samples from relevant rubbing areas on outlet side of the LP rotor at governing end, based on differential expansion conical surface measurement method, after which corresponding countermeasures were put forward and taken. Results show that the measures proposed are proved to be effective, which have broad prospects in engineering applications.

关 键 词:汽轮机 低压缸 动静磨损 振动 

分 类 号:TK268[动力工程及工程热物理—动力机械及工程]

 