作 者:Suman Mondal Arindam Ghosh Khairul Islam Dipankar Bhattacharyya Amitava Bandyopadhyay
机构地区:[1]Department of Physics, Visva-Bharati [2]Department of Physics, Santipur College
出 处:《Chinese Physics B》2018年第9期287-295,共9页中国物理B(英文版)
基 金:Project supported by UGC,New Delhi,India
摘 要:Effect of residual Doppler averaging on the probe absorption in an alkali vapor medium in the presence of a coherent pump beam is studied analytically for the Ξ type system. A coherent probe field is assumed to connect the ground level with the intermediate level whereas a coherent control beam is supposed to act between the intermediate energy level and the uppermost level. Optical Bloch equations(OBE) for a three-level Ξ type system and a four-level Ξ type system are derived by using density matrix formalism. These equations are solved by an analytic method to determine the probe response, which not only depends on the wavelength difference between the control(pump) field and the probe field but shows substantially different features depending on whether the wavelength of the control field is greater than that of the probe field or the reverse. The effect of temperature on probe response is also shown. Enhancement in probe absorption and additional features are noticed under a strong probe limit at room temperature. The four-level Ξ type system has two ground levels and this leads to substantial modification in the simulated probe absorption as compared to the three-level system.Effect of residual Doppler averaging on the probe absorption in an alkali vapor medium in the presence of a coherent pump beam is studied analytically for the Ξ type system. A coherent probe field is assumed to connect the ground level with the intermediate level whereas a coherent control beam is supposed to act between the intermediate energy level and the uppermost level. Optical Bloch equations(OBE) for a three-level Ξ type system and a four-level Ξ type system are derived by using density matrix formalism. These equations are solved by an analytic method to determine the probe response, which not only depends on the wavelength difference between the control(pump) field and the probe field but shows substantially different features depending on whether the wavelength of the control field is greater than that of the probe field or the reverse. The effect of temperature on probe response is also shown. Enhancement in probe absorption and additional features are noticed under a strong probe limit at room temperature. The four-level Ξ type system has two ground levels and this leads to substantial modification in the simulated probe absorption as compared to the three-level system.
关 键 词:cascade type system density matrix method residual Doppler averaging electromagnetically induced transparency(EIT)
分 类 号:O562[理学—原子与分子物理]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.23.61.129