小型公建消防应急照明和疏散指示系统设计  被引量:1

Design of Fire Emergency Lighting and Evacuate Indicating System for Small Public Buildings

在线阅读下载全文

作  者:姚志渊 YAO Zhiyuan(Tibet Changdu Architectural Survey & Design Institute,Changdu 854000,Tibet Autonomous Region,China)

机构地区:[1]西藏昌都市建筑勘察设计院,西藏自治区昌都市854000

出  处:《建筑电气》2018年第9期49-52,共4页Building Electricity

摘  要:指出无火灾自动报警系统的单、多层公共建筑消防应急应急照明和疏散指示系统几种常见做法的缺陷,提出解决方案:建议采用自带蓄电池的应急照明灯作为日常照明的一部分;采用24 V输出的小型集中EPS供电;增加强制启动设计,设置消防报警(兼启动)按钮。Some common defects of the fire emergency lighting and evacuate indicating system for the single-story and multi-storey public buildings without automatic fire alarm systems are pointed out, and the solutions are put forward: it is recommended to use the emergency lamps with batteries as a part of daily lighting, take 24 V output small-sized centralized EPS as the power supply, and add the force start and a fire alarm (start concurrently) button.

关 键 词:小型公共建筑 消防应急照明 疏散指示系统 应急照明灯具 EPS 强制启动 消防报警(兼启动)按钮 24V输出 

分 类 号:TU892[建筑科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象