抗裂新技术在北京新机场墙体试验段中的应用  

APPLICATION OF ANTI-CRACK TECHNOLOGY IN THE WALL TEST SECTION OF CAPITAL NEW AIRPORT

在线阅读下载全文

作  者:雷素素 贾福杰[2] 李建华[1] 张显达[1] 苏振华 LEI Su-su;JIA Fu-jie;LI Jian-hua;ZHANG Xian-da;SU Zhen-hua(Beijing Urban Construction Group Co.,Ltd.,100088,Beijing,China;China Building Materials Academy,100024,Beijing,China)

机构地区:[1]北京城建集团有限责任公司,北京100088 [2]中国建筑材料科学研究总院,北京100024

出  处:《建筑技术》2018年第9期934-937,共4页Architecture Technology

基  金:北京市科技计划课题(Z161100005116009)

摘  要:北京新机场航站楼墙体试验段采用HCSA-R水化热抑制型冷缩-干缩全补偿混凝土为核心抗裂技术,辅以"互联网+"水泥基材料全程变形、应变及温度监控技术。试验结果证明,应用该技术可显著提高墙体抗裂能力,混凝土水化放热平缓,降低最高温升10.4℃,降低开裂几率90%。HCSA-R hydration heat inhibitable thermal shrinkage-drying shrinkage full compensation concrete was taken as the core anti-crack technique. "Internet+" monitoring technology was also used as assistance, such as the whole deformation, strain and temperature for cementitious materials, to solve the cracking problems of the wall test section of capital new airport. Results show that the application of anti-cracking significantly improves the anti-crack ability of the wall. The whole hydration heat of test section concrete level off, and the peak temperature rise decreases 10.4℃. above all the cracking rate of wall reduce 90%.

关 键 词:HCSA-R水化热抑NN 冷缩-干缩全补偿 抗裂技术 互联网+ 

分 类 号:TU7[建筑科学—建筑技术科学]

 