作 者:熊冬庆[1] 石红[1] 王娅琦[1] 邓天勇 郑向阳[1] Xiong Dongqing , Shi Hong, WangYaqi, Deng Tianyong , Zheng Xiang yang(1. Nuclear and Radiation Safety Center, MEP, Beijing 100082, China; 2. The 719th Research Institute of CSIC, Wuhan 43(X)64, China)
机构地区:[1]环境保护部核与辐射安全中心,北京100082 [2]中国船舶重工集团公司第七一九研究所,武汉430064
出 处:《核安全》2018年第4期17-23,共7页Nuclear Safety
摘 要:核电厂主设备阻尼器综合试验台架为核电厂蒸汽发生器、稳压器、主泵等主设备阻尼器实施动态和静态试验,文章对核电厂主设备阻尼器综合试验台架整体方案设计及主要系统进行了介绍,对执行元件和控制元件两类关键设备进行了详细的计算分析和选型。The comprehensive test bench of damper is implement the dynamic test and captive test to damper used for nuclear power station primary equipment , including Steam Generator, Pressurizer and Primary Pump. This paperpresents of the overall scheme design and the main systemof the damper test bench, Detailed Calculation analysis and selection of the executive components and control components are carried out.