检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张怡真 金涛[1] Zhang Yizhen;Jin Tao(College of Electrical Engineering and Automation,Fuzhou University,Fuzhou 350108)
机构地区:[1]福州大学电气工程与自动化学院,福州350108
出 处:《电气技术》2018年第9期19-22,27,共5页Electrical Engineering
基 金:欧盟FP7国际科技合作基金(909880);国家自然科学基金资助项目(61304260)
摘 要:当配电网发生单相接地故障时,故障点同侧的暂态零序电流具有一致的主谐振频率,而故障点两侧的电流主谐振频率差异较大。根据这一特征,本文提出了一种基于自适应噪声的完备集合经验模态分解(CEEMDAN)能量相对熵的故障区段定位方法来识别此差异,计算得到熵值最大的区段即可判断为故障区段。经仿真分析,该方法在不同的故障条件下均能定位出故障区段,且不受噪声影响,具有很高的准确性和可靠性。When a single-phase ground fault occurs in the distribution network, the spectral energy distributions on both sides of the fault point are different. Based on this feature, a fault section location method based on the complete empirical mode decomposition with adaptive noise (CEEMDAN) energy relative entropy is proposed to identify this difference. The simulation analysis shows that the method can locate the fault section under different fault conditions and is not affected by noise, which has high accuracy and reliability.
关 键 词:单相接地故障 区段定位 CEEMDAN 能量相对熵
分 类 号:TM862[电气工程—高电压与绝缘技术]