电站锅炉TP304H高温过热器管泄漏原因分析  被引量:3

Leakage Reason Analysis of TP304H High Temperature Superheater Tube in Power Station Boiler

在线阅读下载全文

作  者:郑坊平[1] 刘谋训 宋少平[1] 刘佳伟[1] ZHENG Fangping;LIU Mouxun;SONG Shaoping;LIU Jiawei(Thermal Power Research Institute,Xi'an 710032,China;Ningxia Zhaoquan Power Generation Co.,Ltd.,Yinchuan 750041,China)

机构地区:[1]西安热工研究院有限公司,陕西西安710032 [2]宁夏枣泉发电有限责任公司,宁夏银川750041

出  处:《铸造技术》2018年第9期2112-2116,共5页Foundry Technology

摘  要:通过宏观检查、化学成分分析、金相检验、力学性能测定、能谱分析及综合分析,对电站锅炉TP304H高温过热器管的泄漏原因进行了研究。结果表明,开裂泄漏的主要原因是应力腐蚀,是锅炉燃烧导致的烟气温度偏高,煤粉中S含量较高促进了开裂。The leakage reason of TP304H high temperature superheater tube in power station boiler was analyzed by means of macroscopic test, composition analysis, metallographic examination, mechanics properties testing, energy spectrum analysis and comprehensive analysis. The results show that the type of cracking leakage is stress corrosion. The main reason is the higher flue gas temperature caused by boiler burning problems. The higher S content in pulverized coal promotes the cracking. Finally, the relevant preventive measures are put forward.

关 键 词:TP304H钢 泄漏 应力腐蚀 烟气温度 

分 类 号:TG142.71[一般工业技术—材料科学与工程]

 