基于等效热降法的引射汇流装置节能效果分析  被引量:1

Analysis on Energy Conservation Effect of Injection Afflux Installment Based on Equivalent Enthalpy Drop Method

在线阅读下载全文

作  者:郑威 丁俊齐 王立刚 祝令凯 韩悦 郭俊山 刘军 ZHENG Wei;DING Jun-qi;WANG Li-gang;ZHU Ling-kai;HAN Yue;GUO Jun-shan;LIN Jun(State Grid Shandong Electric Power Research Institute?Jinan 250002? China;Datang Lubei Power Generation Company Limited? Binzhou 256600? China)

机构地区:[1]国网山东省电力公司电力科学研究院,济南250002 [2]大唐鲁北发电有限责任公司,滨州256600

出  处:《汽轮机技术》2018年第5期379-381,共3页Turbine Technology

摘  要:为实现热能按质利用,采用引射汇流装置实现再热冷段与五段抽汽联合供汽,替代原有从再热热段减温减压后的对外供汽方式;采用等效热降法对某330MW热电联产机组进行了计算,结果表明,机组负荷在250MW以上时,采用引射汇流装置节能效果明显。To make use of thermal energy according to the quality,the injection afflux installment is adopted to realize the combined steam supply by the reheat cooling section steam with the steam of the fifth section extraction,which can replace the original heating mode that reheat steam after depressurization. Equivalent entropy drop method is used for a 330 MW cogeneration unit calculation. Results show that there is an obvious energy-saving enhancement for heat supply by using the injection afflux installment,when the unit load is above 250 MW.

关 键 词:引射汇流 等效热降法 经济性 

分 类 号:TM621.4[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象