摘  要:玻璃工厂液氨罐区为危险化学品重大危险源。为保证液氨罐区的安全运行,应以预防为主,注重安全设计。该文依据国家有关液氨罐区的新规范和新规定,分析了玻璃工厂液氨罐区重大危险源等级,介绍了液氨罐区电气设计主要安全措施。The glass factory liquid ammonia tank area is a major hazard source for hazardous chemicals.To ensure the safe operation of the liquid ammonia tank area,it should be based on prevention and pay attention to safety design.According to the new law and regulations of the national liquid ammonia tank area,this paper analyzes the major hazard source level of the liquid ammonia tank area of the glass factory,and introduces the main safety measures for the electrical design of the liquid ammonia tank area.

关 键 词:玻璃工厂 液氨罐区 电气安全 